I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Inkcazo emfutshane:

I-KCO SFP+ 10G ER ngumgangatho weentambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngokukodwa ukuhanjiswa komgama omde.

Ivumela ukudluliselwa kwedatha ukuya kuthi ga kwi-40 km ngaphezulu kwefayibha yemowudi enye (i-SMF) kubude bobude be-1550nm.

Iimodyuli ze-fiber optic ze-KCO SFP+ 10G ER, ezidla ngokusetyenziswa njengee-transceivers ze-SFP+, zisetyenziswa kwizicelo ezahlukeneyo apho kufuneka ukufikelela okude, njengokudibanisa izakhiwo kwikhampasi enkulu okanye ngaphakathi kwenethiwekhi yendawo yesixeko.


Iinkcukacha zeMveliso

Iithegi zeMveliso

I-KCO-SFP+-10G-ER

+ I-KCO SFP+ 10G ER ngumgangatho weentambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngokukodwa ukuhanjiswa komgama omde.

+ Ivumela ukudluliselwa kwedatha ukuya kuthi ga kwi-40 km ngaphezulu kwefayibha yemowudi enye (i-SMF) kubude be-1550nm.

Iimodyuli ze-fiber optic ze-+KCO SFP+ 10G ER, ezidla ngokusetyenziswa njengee-transceivers ze-SFP+, zisetyenziswa kwizicelo ezahlukeneyo apho kufuneka ukufikelela okude, njengokudibanisa izakhiwo kwikhampasi enkulu okanye ngaphakathi kwenethiwekhi yendawo yesixeko.

Iimpawu zeMveliso

+ Iikhonkco zeDatha ezifikelela kwi-11.1Gbps

+ Ukudluliselwa kwe-SMF ukuya kuthi ga kwi-40km

+ Umthumeli we-EML kunye ne-PIN receiver

+ Ukuvalwa kwesinyithi, kwe-EMI esezantsi

+ Ujongano lweengcingo ezimbini olunenkqubo edibeneyo yokujonga iDijithali

+ Unyawo lwe-SFP+ olutshixwayo olushushu

+ Iinkcukacha ziyahambelana ne-SFF 8472

+ Iyahambelana ne-SFP+ MSA kunye nesixhumi se-LC

+ Umbane omnye we-3.3V

+ Uluhlu lobushushu bokusebenza kwetyala: 0°C ukuya kwi-70°C

+ Ukusasazwa kwamandla < 1.5 W

Izicelo

+ 10GBASE-ER/EW & 10G Ethernet

Umgangatho

+ Iyahambelana ne-SFF-8431

+ Iyahambelana ne-SFF 8472

+ I-RoHS ehambelanayo.

Uvavanyo olupheleleyo olupheleleyo

Ipharamitha

Isimboli

Ubuncinci.

Uhlobo.

UMax.

Iyunithi

Ubushushu bokugcina

Ts

-40

-

85

ºC

Ubuntu bezizalwane

RH

5

-

95

%

Umbane woNikezo lweVolthi

I-VCC

-0.3

-

4

V

I-Voltage yokufaka uphawu

I-Vcc-0.3

-

I-Vcc+0.3

V

Iimeko Zokusebenza Ezicetyiswayo

Ipharamitha

Isimboli

Ubuncinci.

Uhlobo.

UMax.

Iyunithi

Phawula

Ubushushu bokusebenza kweTyala

Tityala

0

-

70

ºC

Ngaphandle kokuhamba komoya

Umbane woNikezo lweVolthi

I-VCC

3.14

3.3

3.47

V

Ubonelelo lwaMandla lwangoku

I-ICC

-

450

mA

Ixabiso leDatha

BR

10.3125

I-Gbps

Umgama woThutho

TD

-

40

km

Ifayibha edibeneyo

Ifayibha yemo enye

9/125um SMF

Iimpawu zoBuchule

Ipharamitha

Isimboli

Ubuncinci.

Uhlobo.

UMax.

Iyunithi

Phawula

Umthumeli

Amandla Aphakathi Aqalisiweyo

PO

-1

+3

i-dBm

Inqaku (1)

Umlinganiselo wokuphela

ER

6

dB

Ubude beWave ephakathi

λc

1530

1550

1565

nm

Ububanzi bebhendi yeSpectrum (RMS)

σ

1.0

nm

I-SMSR

30

dB

Amandla okuphuma eTransmitter OFF

I-PFoff

-30

i-dBm

Isohlwayo somthumeli kunye nokusasazwa

I-TDP

3.0

dB

Imaski Yamehlo Ephumayo

Iyahambelana ne-IEEE 802.3ae

Umamkeli

Igalelo le-Optical Wavelength

λ

1270

1610

nm

Uvakalelo loMmkeli

I-Psen

-15.8

i-dBm

Inqaku (2)

Amandla Okugcwalisa Okufaka (Ukulayisha Okugqithisileyo)

I-Psat

0.5

i-dBm

Amandla okuqinisekisa e-LOS Detect

PA

-28

i-dBm

I-LOS Detect - Amandla eDeassert

PD

-19

i-dBm

I-LOS Fumana i-Hysteresis

I-PHYS

0.5

dB

Phawula:
1. Amandla aqalisiweyo (umndilili) ngamandla adityaniswe kwifayibha yemowudi enye enesixhobo esiphambili sokudibanisa. (Ngaphambi koBomi)
2. Ilinganiswe ngesignali yovavanyo lokuvumelana kwe-BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Iimpawu zoMbane

Ipharamitha

Isimboli

Ubuncinci

Uhlobo

Ubuninzi

Iyunithi

PHAWULA

I-Voltage yokubonelela

I-Vcc

3.14

3.3

3.46

V

Ubonelelo lwangoku

I-Icc

450

mA

Umthumeli

Impedance yokwahluka yokufaka

Rin

100

Ω

1

Utshintsho lokufaka idatha olupheleyo olunye

Vin,pp

180

700

mV

Dlulisa Khubaza iVolthi

VD

I-Vcc–1.3

I-Vcc

V

Thumela Vumela iVoltage

I-VEN

UVee

I-Vee+ 0.8

V

2

Ixesha lokuQinisekisa lokuKhubaza ukuThumela

10

us

Umamkeli

Utshintsho lokukhupha idatha eyahlukileyo

Vout,pp

300

850

mV

3

Ixesha lokunyuka kwemveliso yedatha

tr

28

ps

4

Ixesha lokuwa kwemveliso yedatha

tf

28

ps

4

Impazamo yeLOS

Impazamo yeVLOS

I-Vcc–1.3

I-VccHOST

V

5

I-LOS Eqhelekileyo

Isiqhelo se-VLOS

UVee

I-Vee+0.8

V

5

Ukwaliwa kobonelelo lwamandla

I-PSR

100

mVpp

6

Amanqaku:

  1. Iqhagamshelwe ngqo kwiiphini zokufaka idatha ze-TX. I-AC idityaniswe emva koko.
  2. Okanye isekethe evulekileyo.
  3. Ukuphelisa umahluko kwi-100 ohms.
  4. 20 – 80%.
  5. Ukulahleka kweSignali yi-LVTTL. I-Logic 0 ibonisa ukusebenza okuqhelekileyo; i-logic 1 ibonisa ukuba akukho signali ifunyenweyo.

Uvakalelo lwesamkeli luhambelana nokuguqulwa kwe-sinusoidal yombane ukusuka kwi-20 Hz ukuya kwi-1.5 MHz ukuya kuthi ga kwixabiso elithile elisetyenziswa ngenethiwekhi yokucoca umbane ecetyiswayo.

Inkcazo yePin

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Phina

Isimboli

Igama/Inkcazo

PHAWULA

1

Vi-EET

Umhlaba weTransmitter (oqhelekileyo kwiReceiver Ground)

1

2

TIMFALELO

Impazamo yoMthumeli.

2

3

TI-DIS

Ukungasebenzi kweTransmitter. Ukuphuma kwelaser kuvaliwe xa kuvuliwe okanye kuphezulu.

3

4

I-SDA

Umgca weDatha yoNxibelelwano lweSerial oluneengcingo ezimbini

4

5

I-SCL

Umgca wewotshi ye-Serial Interface eneengcingo ezimbini

4

6

MOD_ABS

Imodyuli ayikho. Isekelwe ngaphakathi kwimodyuli

4

7

I-RS0

Ireyithi Khetha u-0

5

8

I-LOS

Ukulahleka kwesalathisi seSignali. I-Logic 0 ibonisa ukusebenza okuqhelekileyo.

6

9

I-RS1

Akukho qhagamshelo lufunekayo

1

10

VI-EER

Indawo yokwamkela (eqhelekileyo kwindawo yokuhambisa)

1

11

VI-EER

Indawo yokwamkela (eqhelekileyo kwindawo yokuhambisa)

1

12

RD-

I-Receiver Inverted DATA iphumile. I-AC idibene

13

RD+

Umamkeli I-DATA engaguqukiyo iphumile. I-AC idibene

14

VI-EER

Indawo yokwamkela (eqhelekileyo kwindawo yokuhambisa)

1

15

VI-CCR

Ubonelelo lwaMandla oMmkeli

16

VI-CCT

Ubonelelo lwaMandla oMdlulisi

17

Vi-EET

Umhlaba weTransmitter (oqhelekileyo kwiReceiver Ground)

1

18

TD+

I-Transmitter Engaguqukiyo I-DATA kwi-AC Edibeneyo.

19

TD-

I-Transmitter Inverted DATA kwi. I-AC edibeneyo.

20

Vi-EET

Umhlaba weTransmitter (oqhelekileyo kwiReceiver Ground)

1

Amanqaku:

  1. Umhlaba wesekethe uhlukaniswe ngaphakathi nomhlaba we-chassis.
  2. TIMFALELOyimveliso evulekileyo yokuqokelela/yokukhupha amanzi, ekufuneka itsalwe phezulu nge-resistor ye-4.7k – 10k Ohms kwibhodi yokusingatha ukuba yenzelwe ukusetyenziswa. I-voltage yokutsala kufuneka ibe phakathi kwe-2.0V ukuya kwi-Vcc + 0.3VA imveliso ephezulu ibonisa isiphene somthumeli esibangelwa yi-TX bias current okanye amandla okukhupha e-TX adlula imida ye-alamu esetwe kwangaphambili. Imveliso ephantsi ibonisa ukusebenza okuqhelekileyo. Kwimeko ephantsi, imveliso itsalwa ukuya kwi-<0.8V.
  3. Ukuphuma kwelaser kukhutshaziwe kwi-TI-DIS>2.0V okanye ivuliwe, ivuliwe kwi-TI-DIS<0.8V.
  4. Kufuneka itsalwe phezulu ngebhodi yokusingatha ye-4.7kΩ- ​​10kΩ ukuya kwi-voltage ephakathi kwe-2.0V kunye ne-3.6V. I-MOD_ABS itsala umgca osezantsi ukubonisa ukuba imodyuli ixhunyiwe.
  5. Itsalwe ngaphakathi ngokwe-SFF-8431 Rev 4.1.
  6. I-LOS yimveliso evulekileyo yokuqokelela. Ifanele itsalwe phezulu nge-4.7kΩ – 10kΩ kwibhodi yokusingatha ukuya kwi-voltage ephakathi kwe-2.0V kunye ne-3.6V. I-Logic 0 ibonisa ukusebenza okuqhelekileyo; i-logic 1 ibonisa ukulahleka kwesiginali.

Imisebenzi yokuxilonga yedijithali

Ii-transceivers ze-OP-SFP+-ER zixhasa iprotocol yonxibelelwano lwe-serial ye-2-wire njengoko ichazwe kwi-SFP+MSA.

I-SFP serial ID eqhelekileyo inika ukufikelela kulwazi lokuchonga oluchaza izakhono ze-transceiver, i-interfaces eqhelekileyo, umenzi, kunye nolunye ulwazi.

Ukongeza, ii-transceivers ze-SFP+ zibonelela nge-interface yokujonga uxilongo lwedijithali ephuculweyo, evumela ukufikelela ngexesha langempela kwiiparameter zokusebenza kwesixhobo ezifana nobushushu be-transceiver, i-laser bias current, amandla e-optical adluliselweyo, amandla e-optical afunyenweyo kunye ne-transceiver supply voltage. Ikwachaza inkqubo enobuchule ye-alamu kunye neeflegi zesilumkiso, ezilumkisa abasebenzisi bokugqibela xa iiparameter ezithile zokusebenza zingaphandle koluhlu oluqhelekileyo olusetwe ngumzi-mveliso.

I-SFP MSA ichaza imephu yememori ye-256-byte kwi-EEPROM enokufikeleleka nge-interface ye-serial ye-2-wire kwidilesi ye-8 bit 1010000X (A0h). I-interface yokujonga ukuxilongwa kwedijithali isebenzisa idilesi ye-8 bit 1010001X (A2h), ngoko ke imephu yememori ye-serial ID echazwe ekuqaleni ayitshintshanga.

Ulwazi lokusebenza noluxilongo lujongwa kwaye luxelwa yiDigital Diagnostics Transceiver Controller (DDTC) ngaphakathi kwi-transceiver, efikelelwa nge-interface ye-serial ene-wire 2. Xa i-serial protocol isebenza, isignali ye-serial clock (SCL, Mod Def 1) iveliswa yi-host. I-positive edge ifaka idatha kwi-SFP transceiver kwezo zigaba ze-E2PROM ezingakhuselekanga. I-negative edge ifaka idatha kwi-SFP transceiver. I-serial data signal (SDA, Mod Def 2) i-bi-directional yokudluliselwa kwedatha ye-serial. I-host isebenzisa i-SDA kunye ne-SCL ukuphawula ukuqala nokuphela kokusebenza kwe-serial protocol. Iimemori zihlelwe njengoluhlu lwamagama edatha ye-8-bit anokujongwana nawo ngokwahlukeneyo okanye ngokulandelelana.

Isekethe yoNxibelelwano eCetyisiweyo

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Ubukhulu boMxholo

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Ukuthotyelwa kweMithetho

Uphawu

Isalathiso

Ukusebenza

Ukukhutshwa kwe-electrostatic (ESD)

I-IEC/EN 61000-4-2

Iyahambelana nemigangatho

Ukuphazamiseka kwe-Electromagnetic (EMI)

ICandelo le-FCC Icandelo 15 Udidi B EN 55022 Udidi B (CISPR 22A)

Iyahambelana nemigangatho

Ukhuseleko lwamehlo ngeLaser

I-FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Imveliso yelaser yeKlasi 1

iiROHS

2002/95/EC

Iyahambelana nemigangatho

I-EMC

EN61000-3

Iyahambelana nemigangatho

Isihlomelo A. Uhlaziyo loxwebhu

Inombolo yenguqulelo

Umhla

Inkcazo

1.0

2010-09-01

Iphepha ledatha lokuqala

2.0

2011-09-10

Hlaziya ifomathi kunye nelogo yenkampani

3.0

2012-08-03

Hlaziya i-power spec -1~4 ukuya kwi -1~3


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi