Ibhena ye-KCO-Fiver-MTP-MPO-QSFP-iphepha-1

I-SFP+/QSFP

I-SFP vs QSFP
I-SFP I-QSFP
I-transceiver ye-SFP (Small Form-factor Pluggable) isebenzisa itshaneli enye ukuhambisa nokufumana idatha I-QSFP (iQuad Small Form-factor Pluggable) idibanisa iziteshi ezine kwimodyuli enye ukuze ifikelele kwi-bandwidth ephindwe kane.
I-SFP (1 Lane): Inendawo encinci enomzila omnye wokudlulisa (Tx) kunye nokwamkela (Rx). Ngokwesiko isebenzisa izihlanganisi ze-LC duplex okanye ze-SC simplex. I-QSFP (Iindlela ezi-4): Inendawo ebanzi. Ineendlela ezine zokudlulisa ezizimeleyo kunye neendlela ezine zokwamkela ezizimeleyo. Ngokwesiqhelo isebenzisa izihlanganisi ze-MPO/MTP ezinoxinano oluphezulu (kwii-parallel optics) okanye i-multiplexer yangaphakathi phezu kwe-LC duplex (ye-Wavelength Division Multiplexing).
Ifomu Factor Amaxabiso eDatha aPhambili Umgangatho oQhelekileyo / Iindidi Amatyala aqhelekileyo okusetyenziswa
I-SFP 1 Gbps 1G SFP Amakhonkco eshishini elidala
I-SFP+ 10 Gbps 10G SFP+ Iicores zamashishini zanamhlanje
I-SFP28 25 Gbps 25G SFP28 Amaziko edatha e-5G FTTA /
I-SFP56 50 Gbps 50G SFP56 Ikhompyutha engenazingcingo ephakathi, ekhethekileyo
QSFP+ 40 Gbps (4 x 10G) Isiseko se-40G-SR4 / LR4 Iileya zokusasazwa kweshishini
QSFP28 100 Gbps (4 x 25G) Isiseko se-100G-SR4 / LR4 Amalaphu e-data center-spine
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Iiklusta ze-AI kunye neziseko zelifu
Imodyuli ye-KCO-GLC-EX-SMD 1000BASE-EX SFP 1310nm 40km DOM Duplex LC SMF Fiber Optic Transceiver

Imodyuli ye-KCO-GLC-EX-SMD 1000BASE-EX SFP 1310nm 40km DOM Duplex LC SMF Fiber Optic Transceiver

- Iikhonkco zeDatha ezifikelela kwi-1.25Gb/s

- Ishushu-Inokutsalwa

- Umthumeli welaser we-DFB we-1310nm

- Isixhumi se-Duplex LC

- Ukuya kuthi ga kwi-40 km kwi-9/125μm SMF

- Umbane omnye +3.3V

- Ukusasazwa kwamandla aphantsi <1W ngokwesiqhelo

- Uluhlu lobushushu bokusebenza kwezorhwebo: 0°C ukuya kuma-70°C

- Ukuthobela iRoHS

- Iyahambelana ne-SFF-8472

I-1.25Gb/s 1310nm I-SFP Transceiver yemowudi enye

I-1.25Gb/s 1310nm I-SFP Transceiver yemowudi enye

Ii-transceivers zeSmall Form Factor Pluggable (SFP) ziyahambelana neSmall Form Factor Pluggable Multi-Sourcing Agreement (MSA). I-transceiver inamacandelo amane: umqhubi we-LD, i-amplifier enomda, i-FP laser kunye ne-PIN photo-detector. Idatha yemodyuli iqhagamshela ukuya kuthi ga kwi-20km kwi-9/125um single mode fiber.

Isiphumo sokubona singacinywa ngokufaka i-TTL logic ephezulu ye-Tx Disable. I-Tx Fault ibonelelwa ukubonisa ukonakala kwe-laser. Ukulahleka kwesiphumo sesiginali (LOS) kubonelelwa ukubonisa ukulahleka kwesignali yokubona yokufaka yomamkeli okanye imeko yekhonkco neqabane.

I-1.25Gb/s 850nm I-SFP Transceiver ye-Multi-mode 850nm

I-1.25Gb/s 850nm I-SFP Transceiver ye-Multi-mode 850nm

Ii-transceivers ze-KCO-SFP-MM-1.25-550-01 Small Form Factor Pluggable (SFP) ziyahambelana ne-Small Form Factor Pluggable Multi-Sourcing Agreement (MSA).

I-transceiver inamacandelo amane: i-LD driver, i-limiting amplifier, i-VCSEL laser kunye ne-PIN photo-detector. Idatha yemodyuli iqhagamshela ukuya kuthi ga kwi-550m kwi-50/125um multimode fiber.

Isiphumo sokubona singacinywa ngokufaka i-TTL logic ephezulu ye-Tx Disable. I-Tx Fault ibonelelwa ukubonisa ukonakala kwe-laser. Ukulahleka kwesiphumo sesiginali (LOS) kubonelelwa ukubonisa ukulahleka kwesignali yokubona yokufaka yomamkeli okanye imeko yekhonkco neqabane.

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi seCopper 100m Imodyuli yeTransceiver ye-Optical

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi seCopper 100m Imodyuli yeTransceiver ye-Optical

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi seCopper 30m Imodyuli yeTransceiver ye-Optical

iyahambelana neCisco GLC-T / GLC-TE/SFP-GE-T, Mikrotik S-RJ01

I-KCO SFP GE T yimodyuli ye-transceiver yekopolo ehambelana neCisco SFP-GE-T eyilwe, yacwangciswa kwaye yavavanywa ukuba isebenze neeswitshi zeCisco brand kunye nee-routers. Ibonelela ngoqhagamshelo oluthembekileyo lwe-1GbE (1000 Mbps) ngentambo yekopolo, kwiinethiwekhi ezihambelana ne-1000BASE-T, kunye nomgama ophezulu ukuya kuthi ga kwi-100 m.

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

I-KCO SFP+ 10G ER ngumgangatho weentambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngokukodwa ukuhanjiswa komgama omde.

Ivumela ukudluliselwa kwedatha ukuya kuthi ga kwi-40 km ngaphezulu kwefayibha yemowudi enye (i-SMF) kubude bobude be-1550nm.

Iimodyuli ze-fiber optic ze-KCO SFP+ 10G ER, ezidla ngokusetyenziswa njengee-transceivers ze-SFP+, zisetyenziswa kwizicelo ezahlukeneyo apho kufuneka ukufikelela okude, njengokudibanisa izakhiwo kwikhampasi enkulu okanye ngaphakathi kwenethiwekhi yendawo yesixeko.

I-10Gb/s SFP+ Transceiver eshushu enokutsalwa, i-Duplex LC, +3.3V, i-1310nm DFB/PIN, Imowudi enye, i-10km

I-10Gb/s SFP+ Transceiver eshushu enokutsalwa, i-Duplex LC, +3.3V, i-1310nm DFB/PIN, Imowudi enye, i-10km

I-KCO-SFP+-10G-LR yimodyuli ye-transceiver ye-optical ye-10Gb/s encinci kakhulu yezicelo zonxibelelwano lwe-optical kwi-10Gb/s, iguqula umsinga wedatha yombane ye-10Gb/s kunye nesignali ye-optical ye-10Gb/s.

I-KCO-SFP+-SR 10Gb/s 850nm I-Multi-mode SFP+ Transceiver

I-KCO-SFP+-SR 10Gb/s 850nm I-Multi-mode SFP+ Transceiver

Iikhonkco zeDatha ukuya kuthi ga kwi-11.1Gbps
Ukudluliselwa kwe-MMF ukuya kuthi ga kwi-300m
Ukusasazwa kwamandla < 1W
I-VSCEL laser kunye ne-PIN receiver
Ukuvalwa kwesinyithi, kwe-EMI esezantsi
Ujongano lweengcingo ezimbini olune-Digital Diagnostic edibeneyo
Unyawo lwe-SFP+ olutshixwayo olushushu
Iinkcukacha ziyahambelana ne-SFF 8472
Iyahambelana ne-SFP+ MSA kunye nesixhumi se-LC
Umbane omnye we-3.3V
Uluhlu lobushushu bokusebenza kwetyala: 0°C ukuya kwi-70°C

I-KCO-25G-SFP28-LR 25Gb/s BIDI SFP28 SM 10KM Transceiver

I-KCO-25G-SFP28-LR 25Gb/s BIDI SFP28 SM 10KM Transceiver

IngatshatangaIsixhumi se-LCInkxasophezuluto 2Amanani e-bit ye-5Gb/s

Iyahambelana ne-SFP28 MSA

I-interface yombane ihambelana ne-SFF-8431

I-SFP eshushu enokutsalwa28umkhondo weenyawo

Imisebenzi yokuxilonga yedijithali eyakhelwe ngaphakathi

Ukuya kuthi ga kwi-10 km kwi-9/125um SMF G.652

Umbane omnye 3.3V

Ithobela iRoHS6/6

Imveliso yelaser yeKlasi 1 ihambelana ne-EN 60825-1

Uluhlu lobushushu bokusebenza:0ukuya kuma-70/-40℃ ukuya85

Ukusetyenziswa kwamandla <1.2W

I-KCO-25G-SFP28-SR LC Duplex 850nm 100m MMF 25Gb/s 850nm I-Multi-mode SFP28 Transceiver

I-KCO-25G-SFP28-SR LC Duplex 850nm 100m MMF 25Gb/s 850nm I-Multi-mode SFP28 Transceiver

Ukuya kuthi ga kwi-25Iikhonkco zeDatha zeGbps
Ubude obukhulu bekhonkco leekhonkco ezingama-70m kwiikhonkco ze-OM3 okanye ze-100m kwi-OM4 multimode fiber
Ukusasazwa kwamandla < 1W
I-VSCEL laser kunye ne-PIN receiver
Ukuvalwa kwesinyithi, kwe-EMI esezantsi
Ujongano lweengcingo ezimbini olune-Digital Diagnostic edibeneyo
Unyawo lwe-SFP28 olunokutsalwa ngokukhawuleza
Iinkcukacha ziyahambelana ne-SFF 8472
Iyahambelana ne-SFP28 MSA kunye nesixhumi se-LC
Umbane omnye we-3.3V
Uluhlu lobushushu bokusebenza kwebhokisi: Ezorhwebo: 0°C ukuya ku +70°C

I-KCO QSFP+ 40G ER4 40Gb/s QSFP+ SMF 1310 40km Transceiver

I-KCO QSFP+ 40G ER4 40Gb/s QSFP+ SMF 1310 40km Transceiver

Iindlela ezi-4 ze-CWDM uyilo lweMux/Demux

Ukuya kuthi ga kwi-11.1Gbps Izinga ledatha ngobude bexesha

Ukudluliselwa kwe-SMF ukuya kuthi ga kwi-40km nge-FEC.

Iyakwazi ukuxhunywa ngombane

Isinxibelelanisi sokuBeka iliso kwiDijithali yoTshononongo

Iyahambelana neQSFP+ MSA enekhonkco le-LC

Uluhlu lobushushu bokusebenza kwetyala: 0°C ukuya kwi-70°C

Ukusasazwa kwamandla < 3.5 W

I-KCO QSFP+ 40G LR4 LC 40Gb/s QSFP+ LR4 SMF 10km LC Transceiver

I-KCO QSFP+ 40G LR4 LC 40Gb/s QSFP+ LR4 SMF 10km LC Transceiver

Yintoni i-QSFP+ 40G LR4

I-40G QSFP+ LR4 yimodyuli ye-transceiver ye-optical ekwaziyo ukuxhunywa kwi-40 Gigabit Ethernet (40GbE) esebenzisa i-single-mode fiber ukuhambisa idatha ukuya kuthi ga kwiikhilomitha ezili-10. Isebenza ngokudibanisa iziteshi ezine ezahlukeneyo ze-10G kwiintambo ezimbini ze-single-mode fiber kusetyenziswaItekhnoloji yeCWDM, eyahlulwahlulwa ibe ziitshaneli ezine ze-10G kwicala lokwamkela. Le modyuli yaziwa ngoqhagamshelo lwayo oluphezulu, ifom encinci.

I-KCO QSFP+ 40G PLR4 SMF 1310 10km MPO 40GBASE PSM4 LR PLR4 QSFP+ SMF 1310nm 10km MTP/MPO Connector Optical Transceiver Module

I-KCO QSFP+ 40G PLR4 SMF 1310 10km MPO 40GBASE PSM4 LR PLR4 QSFP+ SMF 1310nm 10km MTP/MPO Connector Optical Transceiver Module

* Iyahambelana ne-QSFP MSA

* Umbane omnye +3.3V

* Ubushushu bokusebenza kwezorhwebo: 0oC ukuya +70oC

* Isinxibelelanisi se-MPO/MTP

* I-RoHS iyahambelana

123Okulandelayo >>> Iphepha 1 / 3

Ukusetyenziswa kwe-SFP kunye ne-QSFP kwisisombululo se-FTTH kunye ne-FTTA

Uyilo lweMetric I-FTTH (Ifayibha ukuya ekhaya) I-FTTA (Ifayibha ukuya kwi-Antenna)
Imodyuli yoMda (i-SFP) I-GPON / XGS-PON SFP (i-Simplex SC) I-25G SFP28 eCPRI (iDuplex okanye iBiDi LC)
Imodyuli engundoqo (i-QSFP) Iikhonkco zeNethiwekhi ze-QSFP28 / QSFP-DD Ukuqhekeka kweRadio ye-QSFP28 Port-to-SFP28
Iprotokholi ePhambili Ukufakwa kwe-Ethernet / ATM I-CPRI (4G) / i-eCPRI (5G ipakishwe)
Imfuneko yeXesha Elifutshane Ishishini (0°C ukuya kwi-70°C) ngaphakathi kwe-CO2 Imizi-mveliso (-40°C ukuya kuma-85°C) phezulu kwimasti
Ukusetyenziswa [ IOfisi Ephakathi ye-OLT ] ===( QSFP Uplink )===> [ Iswitshi Engundoqo ]
|
(i-PON SFP)
|
[ I-Passive Slitter ] ——> [ Ekhaya ONT / ONU ]
[ I-BBU Hub / DU ] ===( Ukuqhambuka kweQSFP28 )===> [ Iizibuko zeNqaba zeSFP28 ezi-4x ]
||
(Umboko othe nkqo)
||
[25G SFP28 RRU]
Iinethiwekhi ze-FTTH zixhomekeke kakhulu kwiindlela zePassive Optical Network (PON) ukusasaza i-intanethi ukusuka kwi-Ofisi Ephakathi (CO) ukuya kumakhaya abantu ngabanye. I-SFP28 (25G) Standard: Modern 5G Macro cells zisebenza kwii-transceivers ze-25G SFP28 ezakhelwe ngokukodwa iiprotocol ze-eCPRI (Enhanced Common Public Radio Interface).
Icala le-OLT: I-chassis ye-Optical Line Terminal (OLT) isebenzisa iimodyuli ze-PON SFP ezikhethekileyo (GPON, XGS-PON, okanye 25G-PON). Ezi zahlukile kuba ziyi-BiDi (Bidirectional) simplex SFPs—zisebenzisa isixhumi esinye se-SC ukuhambisa kubude obunye (umz., 1490nm) kwaye zifumane kwenye (umz., 1310nm) ukuze zikhonze ukuya kuthi ga kwiindlu ezingama-32 okanye ezingama-64 phezu komtya omnye wefayibha. Ukuqina Kwemizi-mveliso: Ii-SFT ezibekwe phezulu kwinqaba kufuneka zibe nomlinganiselo wobushushu bemizi-mveliso (-40°C ukuya kuma-85°C) ukuze zikwazi ukumelana nemozulu embi kakhulu yexesha lonyaka. Zihlanganiswe kwiindawo zangaphandle eziqinileyo ezifana neFullAXS okanye i-ODVA ngaphambi kokuba zixhunywe ngqo kwiRemote Radio Unit (RRU)
Icala le-ONT/ONU: Isiphelo senethiwekhi ye-optical esecaleni komthengi ngaphakathi kwekhaya okanye kwishishini sidla ngokusebenzisa iimodyuli eziqhelekileyo ze-1G SFP okanye ze-10G SFP+ ezifakwe kwisango lokuhlala. I-BiDi kunye ne-CWDM: Ukuze kongiwe ubunzima kunye nezixhobo zefayibha kwi-asethi yenqaba, iingcali zihlala zisebenzisa iimodyuli ze-BiDi SFP28 okanye ze-CWDM SFP28, zivumela iibhendi ezininzi zefrikhwensi ukuba zabelane ngemicu embalwa yeglasi.
Ukusetyenziswa kwe-QSFP (I-Central Office Core: Abasebenzisi basekhaya abasebenzisi iimodyuli ze-QSFP. Endaweni yoko, ii-transceivers ze-QSFP28 (100G) okanye ze-QSFP-DD (400G/800G) zisetyenziswa ngaphakathi kwi-Central Office. Zihlanganisa ithrafikhi enkulu edibeneyo evela kumakhadi amaninzi e-PON SFP kwaye ziyihambisa iye phezulu kwi-intanethi ebanzi. Ukusasazwa kwe-Breakout: Endaweni yokusebenzisa iintambo ze-SFP ezingama-24, i-router ye-baseband enoxinano oluphezulu iya kusebenzisa ii-port ze-QSFP28 (100G) kwimo yokuqhawuka. I-port enye ye-QSFP28 ihambelana nentambo ye-trunk ye-MPO eqhawuka ukusuka kwi-1 ukuya kwi-4, ihambisa ngokufanelekileyo iitshaneli ezine ezizimeleyo ze-25G eCPRI ukuya kwiirediyo ezine ezahlukeneyo.

Inkqubo
Inkqubo
Inkqubo