Ibhena ye-KCO-Fiver-MTP-MPO-QSFP-iphepha-1

1×8 1*8 1:8 Uhlobo lwetyhubhu encinci ye-PLC fiber optic splitter

Inkcazo emfutshane:

• Ukulahleka okuphantsi kokufakwa, ilahleko ephezulu yokubuyisela

• Uzinzo oluhle kakhulu lobushushu

• Ukuphinda-phinda okuhle kunye nokutshintshiselana

• Ukunyamezela okugqwesileyo koomatshini

• Ixesha eliqinileyo lokunyanga kunye nolawulo lobushushu

• Imigangatho yovavanyo oluqinileyo kunye neendlela zokuvavanya umgangatho

• Ukhuseleko lwendalo (Ukuthobela i-ROHS)

• Intambo ye-fiber optical patch ingenziwa ngokwezifiso ngokweemfuno zabathengi (Isixhumi/ Ubude/ iphakheji eyenziwe ngokwezifiso…)


Iinkcukacha zeMveliso

Iithegi zeMveliso

Ingcaciso yeMveliso:

I-PLC fiber optic splitter isekelwe kwiteknoloji yesekethe ye-planar Lightwave kunye nenkqubo yokulungelelanisa ngokuchanekileyo, inokwahlulahlula igalelo le-optical elinye/elimbini libe ziimveliso ezininzi ze-optical ngokulinganayo kwaye ichazwa njenge-1*N okanye i-2*N.

I-PLC fiber optic splitter luhlobo lwesixhobo sokulawula amandla e-optical esenziwe kusetyenziswa itekhnoloji ye-silica optical waveguide.

Inobukhulu obuncinci, ukuthembeka okuphezulu, ububanzi bobude bomsebenzi kunye nokufana okuhle phakathi kwetshaneli kunye netshaneli, kwaye isetyenziswa kakhulu kwiinethiwekhi zePON ukufezekisa ukwahlukana kwamandla esignali ye-optical.

I-PLC fiber optic splitter inikezela ngokusebenza okuphezulu kwe-optical, uzinzo oluphezulu kunye nokuthembeka okuphezulu, ihlangabezana neemfuno ezahlukeneyo zesicelo kwiindawo ezahlukeneyo.

I-1x8 PLC fiber optic splitter iza ne-1 input kunye ne-8 output. Ubude bekhebula lokufaka kunye nelokukhupha bunokuba yi-0.6m, 1.0m, 1.5m okanye ngokwezifiso. Ifumaneka ngeentlobo ezininzi zezixhumi ezifana nezi: SC/UPC, SC/APC, LC/UPC, LC/APC,

I-1x8 PLC fiber optic splitter isetyenziswa ngokubanzi kwiibhokisi ezisi-8 ze-rack mount box zesakhelo sokusasazwa, okanye isetyenziswa ngokubanzi kwiibhokisi ezisi-8 ze-outdoor fiber optic distribution box.

Isicelo:

Iinethiwekhi ze-FTTX

Iinethiwekhi zePON

Amakhonkco eCATV

Unxibelelwano lweDatha

Unxibelelwano ngefowuni

Ukusasazwa kweSignali yoBoniso

Uphawu:

Ukulahleka okuphantsi kokufakwa, ilahleko ephezulu yokubuya

Uzinzo oluhle kakhulu lobushushu

Ukuphindaphinda okuhle kunye nokutshintshiselana

Ukunyamezela okugqwesileyo koomatshini

Ixesha lokunyanga eliqinileyo kunye nolawulo lobushushu

Imigangatho yovavanyo oluqinileyo kunye neendlela zomgangatho

Ukhuseleko lwendalo (Ukuthobela i-ROHS)

Intambo ye-fiber optical patch ingenziwa ngokwezifiso ngokweemfuno zabathengi (Isixhumi/ Ubude/ iphakheji eyenziwe ngokwezifiso...)

Ipharamitha:

Uqwalaselo lweZibuko 1*8
Ukulahleka Kokufakwa (dB) Ubuninzi 10.6
Ukulahleka okufanayo (dB) 1.0
I-PDL(dB) 0.25
Ukulahleka okuxhomekeke kwiWavelength (dB) 0.3
Ukulahleka okuxhomekeke kwiqondo lobushushu (-40~85) (dB) 0.4

Qaphela: Le parameter ingasentla yeyokwahlulahlula ngaphandle kwesixhumi.

Uqwalaselo lweZibuko 1*8
Ukulahleka Kokufakwa (dB) Ubuninzi 10.8
Ukulahleka okufanayo (dB) 1.0
I-PDL(dB) 0.2
Ukulahleka Okuxhomekeke Kubude Begagasi (dB) 0.3
Ukulahleka okuxhomekeke kwiqondo lobushushu (-40~85°C) (dB) 0.4

Qaphela: Le parameter ingasentla yeyokwahlulahlula ngesixhobo sokudibanisa.

Uvavanyo olupheleleyo olupheleleyo

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Ubushushu bokugcina

TS

-40

 

+85

°C

Ubushushu bokusebenza kweTyala I-SFP+ -10G-LR

TA

0

 

70

°C

I-SFP+ -10G-LR-I

-40

 

+85

°C

Ubuninzi beVoltage yoNikezelo

I-Vcc

-0.5

 

4

V

Ubuntu bezizalwane

RH

0

 

85

%

Iimpawu zoMbane (PHEZULU = 0 ukuya kuma-70 °C, i-VCC = 3.135 ukuya kuma-3.465 Volts)

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Phawula

I-Voltage yokubonelela

I-Vcc

3.135

 

3.465

V

 

Ubonelelo lwangoku

I-Icc

 

 

430

mA

 

Ukutya umbane

P

 

 

1.5

W

 

Icandelo loMthumeli:
Impedance yokwahluka yokufaka

Rin

 

100

 

Ω

1

Ukunyamezelana kweVolthi ye-DC eNgenayo i-Tx (Ref VeeT)

V

-0.3

 

4

V

 

Ukutshintsha kombane wokufaka okwahlukileyo

Vin,pp

180

 

700

mV

2

Dlulisa Khubaza iVolthi

VD

2

 

I-Vcc

V

3

Thumela Vumela iVoltage

VEN

UVee

 

I-Vee+0.8

V

 

Icandelo loMmkeli:
Ukunyamezelana kweVoltage yeSiphumo esiPheleleyo esinye

V

-0.3

 

4

V

 

I-Rx Output Dif Voltage

Vo

300

 

850

mV

 

Ixesha lokunyuka nokuwa kweRx Output

Tr/Tf

30

 

 

ps

4

Impazamo yeLOS

VImpazamo ye-LOS

2

 

I-VccUMBUKELI

V

5

I-LOS Eqhelekileyo

VIsiqhelo se-LOS

UVee

 

I-Vee+0.8

V

5

Amanqaku:1. Iqhagamshelwe ngqo kwiiphini zokufaka idatha ze-TX. Ukudibanisa i-AC ukusuka kwiiphini ukuya kwi-IC yomqhubi we-laser.
2. Ngokwe-SFF-8431 Rev 3.0.
3. Ukuphelisa umahluko kwi-100 ohms.
4. 20% ~80%.
5. I-LOS yimveliso evulekileyo yokuqokelela. Ifanele itsalwe phezulu nge-4.7k – 10kΩ kwibhodi yokusingatha. Ukusebenza okuqhelekileyo yi-logic 0; ukulahleka kwesiginali yi-logic 1. Umbane ophezulu wokutsalwa yi-5.5V.

IiParameters ze-Optical (TOP = 0 ukuya kwi-70°C, i-VCC = 3.135 ukuya kwi-3.465 Volts)

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Phawula

Icandelo loMthumeli:
Ubude beWave ephakathi

λt

1290

1310

1330

nm

 

ububanzi be-spectral

λ

 

 

1

nm

 

Amandla oMbane aPhakathi

I-Pavg

-6

 

0

i-dBm

1

Amandla okukhanya e-OMA

I-Poma

-5.2

 

 

i-dBm

 

Umbane Ocinyiweyo ngeLaser

Poff

 

 

-30

i-dBm

 

Umlinganiselo wokuphela

ER

3.5

 

 

dB

 

Isohlwayo sokuSasazwa kweTransmitter

I-TDP

 

 

3.2

dB

2

Ingxolo Yobukhulu Obuthelekisekayo

Rin

 

 

-128

dB/Hz

3

Ukunyamezelana kokulahlekelwa yi-Optical Return

 

20

 

 

dB

 

Icandelo loMmkeli:
Ubude beWave ephakathi

λr

1260

 

1355

nm

 

Uvakalelo loMmkeli

USen

 

 

-14.5

i-dBm

4

Uvakalelo oluxinezelekileyo (OMA)

USenST

 

 

-10.3

i-dBm

4

I-Los Assert

I-LOSA

-25

 

-

i-dBm

 

Idizethi yaseLos

I-LOSD

 

 

-15

i-dBm

 

I-Los Hysteresis

I-LOSH

0.5

 

 

dB

 

Ukulayisha kakhulu

ngoMgqibelo

0

 

 

i-dBm

5

Ukubonakaliswa koMmkeli

Rrx

 

 

-12

dB

 

Amanqaku:1. Amanani aphakathi anamandla anika ulwazi kuphela, ngokwe-IEEE802.3ae.
2. Inani le-TWDP lifuna ukuba ibhodi yomsingathi ihambelane ne-SFF-8431. I-TWDP ibalwa kusetyenziswa ikhowudi yeMatlab enikwe kwisiqendu 68.6.6.2 se-IEEE802.3ae.
3. Ukubonakaliswa kwe-12dB.
4. Iimeko zovavanyo lomamkeli oluxinzelelweyo ngokwe-IEEE802.3ae. Uvavanyo lwe-CSRS lufuna ukuba ibhodi yomamkeli ithobele i-SFF-8431.
5. Ukugqithisa kwe-receiver okuchazwe kwi-OMA naphantsi kwemeko enzima kakhulu yoxinzelelo olupheleleyo.

Iimpawu zeXesha

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

UMax.

Iyunithi

Ixesha lokuQinisekisa le-TX_Disable

t_off

 

 

10

us

TX_Disable Ixesha Lokuchasa

t_on

 

 

1

ms

Ixesha Lokuqalisa Faka Ukuseta kwakhona kwe-TX_FAULT

t_int

 

 

300

ms

TX_FAULT ukusuka kwiSiphene ukuya kwiSiqinisekiso

impazamo

 

 

100

us

TX_Disable Ixesha Lokuqalisa Ukuseta ngokutsha

t_reset

10

 

 

us

Ukulahleka kweXesha lokuQinisekisa uphawu lomamkeli

TA,RX_LOS

 

 

100

us

Ukulahleka kweSignali yeSignali yoMmkeli

Td,RX_LOS

 

 

100

us

Ixesha lokutshintsha ixabiso

t_ratesel

 

 

10

us

Ixesha lewotshi ye-Serial ID

iwotshi ye-t_serial

 

 

100

kHz

Isabelo sePin

Umzobo weBhodi yoMququzeleli weBhokisi yoQhagamshelo lweBloko Amanani ePin kunye neGama

imveliso3

Iinkcazo zomsebenzi wePin

I-PIN

Igama

Umsebenzi

Amanqaku

1

I-VeeT Umhlaba womthumeli wemodyuli

1

2

Impazamo ye-Tx Impazamo yesixhobo sokuhambisa imodyuli

2

3

Khubaza i-Tx Ikhubaza iTransmitter; Icima imveliso yelaser yetransmitter

3

4

I-SDL I-2 wire serial interface data input/output (SDA)

 

5

I-SCL Igalelo lewotshi ye-serial interface ye-wire 2 (SCL)

 

6

I-MOD-ABS Imodyuli engekho, qhagamshela kwiVeeR okanye kwiVeeT kwimodyuli

2

7

I-RS0 Linganisa i-select0, ngokuzikhethela lawula isamkeli se-SFP+. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s

 

8

I-LOS Ukulahleka kweSignali yoMmkeli

4

9

I-RS1 Linganisa i-select0, ngokuzithandela lawula i-SFP+ transmitter. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s

 

10

I-VeeR Umhlaba womamkeli wemodyuli

1

11

I-VeeR Umhlaba womamkeli wemodyuli

1

12

RD- Idatha eguqulweyo yomamkeli ibekwe ngaphandle

 

13

RD+ Idatha engaguqukiyo yomamkeli ibekwe ngaphandle

 

14

I-VeeR Umhlaba womamkeli wemodyuli

1

15

I-VccR Ubonelelo lwe-3.3V yesamkeli seModule

 

16

I-VccT Ubonelelo lwe-module transmitter 3.3V

 

17

I-VeeT Umhlaba womthumeli wemodyuli

1

18

TD+ Idatha eguqulweyo yetransmitter ikhutshwe

 

19

TD- Idatha engaguqukiyo yokudlulisela idatha iphumile

 

20

I-VeeT Umhlaba womthumeli wemodyuli

1

Phawula:1. Izikhonkwane zomhlaba zemodyuli mazihlukaniswe kwibhokisi yemodyuli.
2. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.
3. Le pin mayitsalwe phezulu nge-4.7K-10Kohms ukuya kwi-VccT kwimodyuli.
4. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.

Ulwazi kunye noLawulo lwe-EEPROM ye-SFP Module

Iimodyuli ze-SFP zisebenzisa iprotocol yonxibelelwano lwe-serial ye-2-wire njengoko ichaziwe kwi-SFP -8472. Ulwazi lwe-serial ID lweemodyuli ze-SFP kunye neeparameter ze-Digital Diagnostic Monitor zinokufikelelwa nge-I2Ujongano lwe-C kwidilesi i-A0h kunye ne-A2h. Imemori idweliswe kwiTheyibhile 1. Ulwazi oluneenkcukacha lwe-ID (A0h) ludweliswe kwiTheyibhile 2, kunye no-tIinkcukacha zeDDM kwidilesi ye-A2h. Ukuze ufumane iinkcukacha ezithe vetshe ngemephu yememori kunye neenkcazo zebhayithi, nceda ujonge kwi-SFF-8472, “iDigital Diagnostic Monitoring Interface for Optical Transceivers”. Iiparameter zeDDM zilinganisiwe ngaphakathi.

Itafile1. Imephu yeMemori yoKuxilonga yeDijithali (Iinkcazo zeNdawo yeDatha eKhethekileyo).

imveliso1

Itheyibhile 2- I-EEPROM Serial ID Imemori Okuqulathwe (A0h)

Idilesi yeDatha

Ubude

(Ibhayithi)

Igama lika

Ubude

Inkcazo kunye nesiqulatho

IiNdawo zoLwazi oluSisiseko

0

1

Isazisi

Uhlobo lwe-Serial transceiver (03h=SFP)

1

1

Igciniwe

Isihlonzi esongeziweyo sohlobo lwe-transceiver ye-serial (04h)

2

1

Isinxibelelanisi

Ikhowudi yohlobo lwesixhumi se-optical (07=LC)

3-10

8

I-Transceiver

Isiseko se-LR se-10G

11

1

Ukubhala ikhowudi

64B/66B

12

1

BR, Igama eliyiNombolo

Isantya sebhawudi esiqhelekileyo, iyunithi ye-100Mbps

13-14

2

Igciniwe

(0000h)

15

1

Ubude (9um)

Ubude bekhonkco buxhaswa kwi-9/125um fiber, iiyunithi ze-100m

16

1

Ubude (50um)

Ubude bekhonkco buxhaswa kwi-fiber ye-50/125um, iiyunithi ze-10m

17

1

Ubude (62.5um)

Ubude bekhonkco buxhaswa kwi-fiber ye-62.5/125um, iiyunithi ze-10m

18

1

Ubude (ubhedu)

Ubude bekhonkco obuxhaswayo bekopolo, iiyunithi zeemitha

19

1

Igciniwe

 

20-35

16

Igama lomthengisi

Igama lomthengisi we-SFP:I-VIP Fiber

36

1

Igciniwe

 

37-39

3

I-OUI yomthengisi

I-ID ye-OUI yomthengisi we-SFP transceiver

40-55

16

I-PN yomthengisi

Inombolo yendawo: "I-SFP+ -10G-LR” (ASCII)

56-59

4

Umthengisi obhalisiweyo

Inqanaba lokuhlaziya inombolo yenxalenye

60-62

3

Igciniwe

 

63

1

I-CCID

I-byte engabalulekanga kangako yesixa sedatha kwidilesi 0-62
IiNdawo ze-ID ezandisiweyo

64-65

2

Ukhetho

Ibonisa ukuba zeziphi iimpawu ze-optical SFP ezisetyenziswayo

(001Ah = LOS, TX_FAULT, TX_DISABLE zonke ziyaxhaswa)

66

1

BR, ubuninzi

Umda wesantya sebhithi ephezulu, iiyunithi ze-%

67

1

BR, umzuzu

Umlinganiselo wesantya sebhithi ophantsi, iiyunithi ze-%

68-83

16

Umthengisi SN

Inombolo yeserial (ASCII)

84-91

8

Ikhowudi yomhla

I-VIP FiberIkhowudi yomhla wokwenziwa

92-94

3

Igciniwe

 

95

1

I-CCEX

Jonga ikhowudi yeeNdawo ze-ID ezandisiweyo (iidilesi ezingama-64 ukuya kuma-94)
IiNdawo zoLwazi oluKhethekileyo loMthengisi

96-127

32

Iyafundeka

I-VIP Fiberumhla othile, kufundwa kuphela

128-255

128

Igciniwe

Igcinelwe i-SFF-8079

Iimpawu zeMonitor yeDijithali yokuHlola

Idilesi yeDatha

Ipharamitha

Ukuchaneka

Iyunithi

96-97 Ubushushu bangaphakathi beTransceiver ±3.0 °C
100-101 I-Laser Bias yangoku ±10 %
100-101 Amandla okuPhuma kweTx ±3.0 i-dBm
100-101 Amandla Okufaka i-Rx ±3.0 i-dBm
100-101 I-VCC3 Yangaphakathi Yokubonelela Ngevolthi ±3.0 %

Ukuthotyelwa kweMithetho

II-SFP+ -10G-LR ihambelana ne-International Electromagnetic Compatibility (EMC) kunye neemfuno kunye nemigangatho yokhuseleko lwamazwe ngamazwe (jonga iinkcukacha kwiTheyibhile elandelayo).

Ukukhupha ngombane

(ESD) ukuya kwiiphini zombane

I-MIL-STD-883E

Indlela 3015.7

Iklasi 1(>1000 V)
Ukukhupha i-Electrostatic (ESD)

ukuya kwiDuplex LC Receptacle

I-IEC 61000-4-2

I-GR-1089-CORE

Iyahambelana nemigangatho
I-electromagnetic

Ukuphazamiseka (i-EMI)

I-FCC Icandelo 15 Udidi B

I-EN55022 Udidi B (CISPR 22B)

Iklasi yeVCCI B

Iyahambelana nemigangatho
Ukhuseleko lwamehlo ngeLaser I-FDA 21CFR 1040.10 kunye ne-1040.11

EN60950, EN (IEC) 60825-1,2

Iyahambelana ne-laser yeKlasi yoku-1

imveliso.

Isekethe Ecetyiswayo

imveliso4

Isekethe yoNikezelo lwaMandla eBhodi yoMphathi eCetyisiweyo

imveliso5

I-Interface Circuit ecetyiswayo enesantya esiphezulu

Idatha yoBugcisa:

Ubude befayibha 1.0mokanye Elungiselelweyo
Uhlobo loQhagamshelo I-SC,LC,

FC

okanye Elungiselelweyo

Uhlobo lweFiber ye-Optical G652DG657A1

okanye Elungiselelweyo

Isikhokelo (dB) Ubuncinane * 55
Ilahleko yokubuyisela (dB) Ubuncinane * 55 (50)
Ulawulo lwaMandla (mW) 300
Ubude beWave obusebenzayo (nm) 1260 ~ 1650
Ubushushu bokusebenza (°C) -40 ~ +85
Ubushushu bokugcina(°C) -40 ~ +85

Umgca wemveliso:

imveliso_1

  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi