Inkcazo yeMveliso ye-SFP+ -10G-LR:

I-SFP+ -10G-LR yimodyuli ye-transceiver ye-optical ye-10Gb/s encinci kakhulu yezicelo zonxibelelwano lwe-optical kwi-10Gb/s, iguqula umsinga wedatha yombane ye-10Gb/s kunye nesignali ye-optical ye-10Gb/s. Ihambelana ne-SFF-8431, i-SFF-8432 kunye ne-IEEE 802.3ae 10GBASE-LR. Ibonelela ngemisebenzi yokuxilongwa kwedijithali nge-interface ye-serial ye-2-wire njengoko kuchaziwe kwi-SFF-8472. Ine-hot plug, ukuphuculwa okulula kunye nokukhutshwa kwe-EMI ephantsi. I-transmitter ye-1310nm DFB esebenza kakhulu kunye ne-PIN receiver evakalayo ephezulu ibonelela ngokusebenza okuphezulu kwizicelo ze-Ethernet ukuya kuthi ga kubude be-10km kwi-fiber ye-single mode.

Iimpawu ze-SFP+ 10G:

Ixhasa amazinga e-bit ukusuka kwi-9.95 ukuya kwi-11.3Gb/s

Ishushu-Inokutsalwa

Isixhumi se-Duplex LC

Isithumeli se-DFB se-1310nm, isixhobo sokubona ifoto se-PIN

I-SMF idibanisa ukuya kuthi ga kwi-10km

I-interface ye-2-wire yokuhambelana neenkcukacha zolawulo ezihambelanayo
nge-SFF 8472 digital diagnostic monitoring interface

Ubonelelo lwaMandla:+3.3V

Ukusetyenziswa kwamandla<1.5W

Uluhlu lobushushu borhwebo: 0 ~ 70°C

Uluhlu lobushushu kwimizi-mveliso: -40~ +85°C

Ithobela iRoHS

Usetyenziso lwe-SFP+ 10G:

I-Ethernet ye-10GBASE-LR/LW kwi-10.3125Gbps

I-SONET OC-192 / SDH

I-CPRI kunye ne-OBSAI

Itshaneli yeFiber ye-10G

Ulwazi loku-odola:

Inombolo yendawo

Ixabiso leDatha

Umgama

Ubude bamaza

I-laser

Ifayibha

I-DDM

Isinxibelelanisi

Ubushushu

I-SFP+ -10G-LR

10Gb/s

10km

1310nm

I-DFB/IPIN

SM

Ewe

I-DuplexLC

0~ 70°C

I-SFP+ -10G-I-LR-I

10Gb/s

10km

1310nm

I-DFB/IPIN

SM

Ewe

I-DuplexLC

-40~ +85°C

Uvavanyo olupheleleyo olupheleleyo

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Ubushushu bokugcina

TS

-40

 

+85

°C

Ubushushu bokusebenza kweTyala I-SFP+ -10G-LR

TA

0

 

70

°C

I-SFP+ -10G-LR-I

-40

 

+85

°C

Ubuninzi beVoltage yoNikezelo

I-Vcc

-0.5

 

4

V

Ubuntu bezizalwane

RH

0

 

85

%

Iimpawu zoMbane (PHEZULU = 0 ukuya kuma-70 °C, i-VCC = 3.135 ukuya kuma-3.465 Volts)

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Phawula

I-Voltage yokubonelela

I-Vcc

3.135

 

3.465

V

 

Ubonelelo lwangoku

I-Icc

 

 

430

mA

 

Ukutya umbane

P

 

 

1.5

W

 

Icandelo loMthumeli:
Impedance yokwahluka yokufaka

Rin

 

100

 

Ω

1

Ukunyamezelana kweVolthi ye-DC eNgenayo i-Tx (Ref VeeT)

V

-0.3

 

4

V

 

Ukutshintsha kombane wokufaka okwahlukileyo

Vin,pp

180

 

700

mV

2

Dlulisa Khubaza iVolthi

VD

2

 

I-Vcc

V

3

Thumela Vumela iVoltage

VEN

UVee

 

I-Vee+0.8

V

 

Icandelo loMmkeli:
Ukunyamezelana kweVoltage yeSiphumo esiPheleleyo esinye

V

-0.3

 

4

V

 

I-Rx Output Dif Voltage

Vo

300

 

850

mV

 

Ixesha lokunyuka nokuwa kweRx Output

Tr/Tf

30

 

 

ps

4

Impazamo yeLOS

VImpazamo ye-LOS

2

 

I-VccUMBUKELI

V

5

I-LOS Eqhelekileyo

VIsiqhelo se-LOS

UVee

 

I-Vee+0.8

V

5

Amanqaku:1. Iqhagamshelwe ngqo kwiiphini zokufaka idatha ze-TX. Ukudibanisa i-AC ukusuka kwiiphini ukuya kwi-IC yomqhubi we-laser.
2. Ngokwe-SFF-8431 Rev 3.0.
3. Ukuphelisa umahluko kwi-100 ohms.
4. 20% ~80%.
5. I-LOS yimveliso evulekileyo yokuqokelela. Ifanele itsalwe phezulu nge-4.7k – 10kΩ kwibhodi yokusingatha. Ukusebenza okuqhelekileyo yi-logic 0; ukulahleka kwesiginali yi-logic 1. Umbane ophezulu wokutsalwa yi-5.5V.

IiParameters ze-Optical (TOP = 0 ukuya kwi-70°C, i-VCC = 3.135 ukuya kwi-3.465 Volts)

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

Ubuninzi.

Iyunithi

Phawula

Icandelo loMthumeli:
Ubude beWave ephakathi

λt

1290

1310

1330

nm

 

ububanzi be-spectral

λ

 

 

1

nm

 

Amandla oMbane aPhakathi

I-Pavg

-6

 

0

i-dBm

1

Amandla okukhanya e-OMA

I-Poma

-5.2

 

 

i-dBm

 

Umbane Ocinyiweyo ngeLaser

Poff

 

 

-30

i-dBm

 

Umlinganiselo wokuphela

ER

3.5

 

 

dB

 

Isohlwayo sokuSasazwa kweTransmitter

I-TDP

 

 

3.2

dB

2

Ingxolo Yobukhulu Obuthelekisekayo

Rin

 

 

-128

dB/Hz

3

Ukunyamezelana kokulahlekelwa yi-Optical Return

 

20

 

 

dB

 

Icandelo loMmkeli:
Ubude beWave ephakathi

λr

1260

 

1355

nm

 

Uvakalelo loMmkeli

USen

 

 

-14.5

i-dBm

4

Uvakalelo oluxinezelekileyo (OMA)

USenST

 

 

-10.3

i-dBm

4

I-Los Assert

I-LOSA

-25

 

-

i-dBm

 

Idizethi yaseLos

I-LOSD

 

 

-15

i-dBm

 

I-Los Hysteresis

I-LOSH

0.5

 

 

dB

 

Ukulayisha kakhulu

ngoMgqibelo

0

 

 

i-dBm

5

Ukubonakaliswa koMmkeli

Rrx

 

 

-12

dB

 

Amanqaku:1. Amanani aphakathi anamandla anika ulwazi kuphela, ngokwe-IEEE802.3ae.
2. Inani le-TWDP lifuna ukuba ibhodi yomsingathi ihambelane ne-SFF-8431. I-TWDP ibalwa kusetyenziswa ikhowudi yeMatlab enikwe kwisiqendu 68.6.6.2 se-IEEE802.3ae.
3. Ukubonakaliswa kwe-12dB.
4. Iimeko zovavanyo lomamkeli oluxinzelelweyo ngokwe-IEEE802.3ae. Uvavanyo lwe-CSRS lufuna ukuba ibhodi yomamkeli ithobele i-SFF-8431.
5. Ukugqithisa kwe-receiver okuchazwe kwi-OMA naphantsi kwemeko enzima kakhulu yoxinzelelo olupheleleyo.

Iimpawu zeXesha

Ipharamitha

Isimboli

Ubuncinci.

Okuqhelekileyo

UMax.

Iyunithi

Ixesha lokuQinisekisa le-TX_Disable

t_off

 

 

10

us

TX_Disable Ixesha Lokuchasa

t_on

 

 

1

ms

Ixesha Lokuqalisa Faka Ukuseta kwakhona kwe-TX_FAULT

t_int

 

 

300

ms

TX_FAULT ukusuka kwiSiphene ukuya kwiSiqinisekiso

impazamo

 

 

100

us

TX_Disable Ixesha Lokuqalisa Ukuseta ngokutsha

t_reset

10

 

 

us

Ukulahleka kweXesha lokuQinisekisa uphawu lomamkeli

TA,RX_LOS

 

 

100

us

Ukulahleka kweSignali yeSignali yoMmkeli

Td,RX_LOS

 

 

100

us

Ixesha lokutshintsha ixabiso

t_ratesel

 

 

10

us

Ixesha lewotshi ye-Serial ID

iwotshi ye-t_serial

 

 

100

kHz

Isabelo sePin

Umzobo weBhodi yoMququzeleli weBhokisi yoQhagamshelo lweBloko Amanani ePin kunye neGama

imveliso3

Iinkcazo zomsebenzi wePin

I-PIN

Igama

Umsebenzi

Amanqaku

1

I-VeeT Umhlaba womthumeli wemodyuli

1

2

Impazamo ye-Tx Impazamo yesixhobo sokuhambisa imodyuli

2

3

Khubaza i-Tx Ikhubaza iTransmitter; Icima imveliso yelaser yetransmitter

3

4

I-SDL I-2 wire serial interface data input/output (SDA)

 

5

I-SCL Igalelo lewotshi ye-serial interface ye-wire 2 (SCL)

 

6

I-MOD-ABS Imodyuli engekho, qhagamshela kwiVeeR okanye kwiVeeT kwimodyuli

2

7

I-RS0 Linganisa i-select0, ngokuzikhethela lawula isamkeli se-SFP+. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s

 

8

I-LOS Ukulahleka kweSignali yoMmkeli

4

9

I-RS1 Linganisa i-select0, ngokuzithandela lawula i-SFP+ transmitter. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s

 

10

I-VeeR Umhlaba womamkeli wemodyuli

1

11

I-VeeR Umhlaba womamkeli wemodyuli

1

12

RD- Idatha eguqulweyo yomamkeli ibekwe ngaphandle

 

13

RD+ Idatha engaguqukiyo yomamkeli ibekwe ngaphandle

 

14

I-VeeR Umhlaba womamkeli wemodyuli

1

15

I-VccR Ubonelelo lwe-3.3V yesamkeli seModule

 

16

I-VccT Ubonelelo lwe-module transmitter 3.3V

 

17

I-VeeT Umhlaba womthumeli wemodyuli

1

18

TD+ Idatha eguqulweyo yetransmitter ikhutshwe

 

19

TD- Idatha engaguqukiyo yokudlulisela idatha iphumile

 

20

I-VeeT Umhlaba womthumeli wemodyuli

1

Phawula:1. Izikhonkwane zomhlaba zemodyuli mazihlukaniswe kwibhokisi yemodyuli.
2. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.
3. Le pin mayitsalwe phezulu nge-4.7K-10Kohms ukuya kwi-VccT kwimodyuli.
4. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.

Ulwazi kunye noLawulo lwe-EEPROM ye-SFP Module

Iimodyuli ze-SFP zisebenzisa iprotocol yonxibelelwano lwe-serial ye-2-wire njengoko ichaziwe kwi-SFP -8472. Ulwazi lwe-serial ID lweemodyuli ze-SFP kunye neeparameter ze-Digital Diagnostic Monitor zinokufikelelwa nge-I2Ujongano lwe-C kwidilesi i-A0h kunye ne-A2h. Imemori idweliswe kwiTheyibhile 1. Ulwazi oluneenkcukacha lwe-ID (A0h) ludweliswe kwiTheyibhile 2, kunye no-tIinkcukacha zeDDM kwidilesi ye-A2h. Ukuze ufumane iinkcukacha ezithe vetshe ngemephu yememori kunye neenkcazo zebhayithi, nceda ujonge kwi-SFF-8472, “iDigital Diagnostic Monitoring Interface for Optical Transceivers”. Iiparameter zeDDM zilinganisiwe ngaphakathi.

Itafile1. Imephu yeMemori yoKuxilonga yeDijithali (Iinkcazo zeNdawo yeDatha eKhethekileyo).

imveliso1

Itheyibhile 2- I-EEPROM Serial ID Imemori Okuqulathwe (A0h)

Idilesi yeDatha

Ubude

(Ibhayithi)

Igama lika

Ubude

Inkcazo kunye nesiqulatho

IiNdawo zoLwazi oluSisiseko

0

1

Isazisi

Uhlobo lwe-Serial transceiver (03h=SFP)

1

1

Igciniwe

Isihlonzi esongeziweyo sohlobo lwe-transceiver ye-serial (04h)

2

1

Isinxibelelanisi

Ikhowudi yohlobo lwesixhumi se-optical (07=LC)

3-10

8

I-Transceiver

Isiseko se-LR se-10G

11

1

Ukubhala ikhowudi

64B/66B

12

1

BR, Igama eliyiNombolo

Isantya sebhawudi esiqhelekileyo, iyunithi ye-100Mbps

13-14

2

Igciniwe

(0000h)

15

1

Ubude (9um)

Ubude bekhonkco buxhaswa kwi-9/125um fiber, iiyunithi ze-100m

16

1

Ubude (50um)

Ubude bekhonkco buxhaswa kwi-fiber ye-50/125um, iiyunithi ze-10m

17

1

Ubude (62.5um)

Ubude bekhonkco buxhaswa kwi-fiber ye-62.5/125um, iiyunithi ze-10m

18

1

Ubude (ubhedu)

Ubude bekhonkco obuxhaswayo bekopolo, iiyunithi zeemitha

19

1

Igciniwe

 

20-35

16

Igama lomthengisi

Igama lomthengisi we-SFP:I-VIP Fiber

36

1

Igciniwe

 

37-39

3

I-OUI yomthengisi

I-ID ye-OUI yomthengisi we-SFP transceiver

40-55

16

I-PN yomthengisi

Inombolo yendawo: "I-SFP+ -10G-LR” (ASCII)

56-59

4

Umthengisi obhalisiweyo

Inqanaba lokuhlaziya inombolo yenxalenye

60-62

3

Igciniwe

 

63

1

I-CCID

I-byte engabalulekanga kangako yesixa sedatha kwidilesi 0-62
IiNdawo ze-ID ezandisiweyo

64-65

2

Ukhetho

Ibonisa ukuba zeziphi iimpawu ze-optical SFP ezisetyenziswayo

(001Ah = LOS, TX_FAULT, TX_DISABLE zonke ziyaxhaswa)

66

1

BR, ubuninzi

Umda wesantya sebhithi ephezulu, iiyunithi ze-%

67

1

BR, umzuzu

Umlinganiselo wesantya sebhithi ophantsi, iiyunithi ze-%

68-83

16

Umthengisi SN

Inombolo yeserial (ASCII)

84-91

8

Ikhowudi yomhla

I-VIP FiberIkhowudi yomhla wokwenziwa

92-94

3

Igciniwe

 

95

1

I-CCEX

Jonga ikhowudi yeeNdawo ze-ID ezandisiweyo (iidilesi ezingama-64 ukuya kuma-94)
IiNdawo zoLwazi oluKhethekileyo loMthengisi

96-127

32

Iyafundeka

I-VIP Fiberumhla othile, kufundwa kuphela

128-255

128

Igciniwe

Igcinelwe i-SFF-8079

Iimpawu zeMonitor yeDijithali yokuHlola

Idilesi yeDatha

Ipharamitha

Ukuchaneka

Iyunithi

96-97 Ubushushu bangaphakathi beTransceiver ±3.0 °C
100-101 I-Laser Bias yangoku ±10 %
100-101 Amandla okuPhuma kweTx ±3.0 i-dBm
100-101 Amandla Okufaka i-Rx ±3.0 i-dBm
100-101 I-VCC3 Yangaphakathi Yokubonelela Ngevolthi ±3.0 %

Ukuthotyelwa kweMithetho

II-SFP+ -10G-LR ihambelana ne-International Electromagnetic Compatibility (EMC) kunye neemfuno kunye nemigangatho yokhuseleko lwamazwe ngamazwe (jonga iinkcukacha kwiTheyibhile elandelayo).

Ukukhupha ngombane

(ESD) ukuya kwiiphini zombane

I-MIL-STD-883E

Indlela 3015.7

Iklasi 1(>1000 V)
Ukukhupha i-Electrostatic (ESD)

ukuya kwiDuplex LC Receptacle

I-IEC 61000-4-2

I-GR-1089-CORE

Iyahambelana nemigangatho
I-electromagnetic

Ukuphazamiseka (i-EMI)

I-FCC Icandelo 15 Udidi B

I-EN55022 Udidi B (CISPR 22B)

Iklasi yeVCCI B

Iyahambelana nemigangatho
Ukhuseleko lwamehlo ngeLaser I-FDA 21CFR 1040.10 kunye ne-1040.11

EN60950, EN (IEC) 60825-1,2

Iyahambelana ne-laser yeKlasi yoku-1

imveliso.

Isekethe Ecetyiswayo

imveliso4

Isekethe yoNikezelo lwaMandla eBhodi yoMphathi eCetyisiweyo

imveliso5

I-Interface Circuit ecetyiswayo enesantya esiphezulu

Ubukhulu boomatshini

imveliso2

  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi