Ibhena ye-KCO-Fiver-MTP-MPO-QSFP-iphepha-1

I-SFP+/QSFP

I-SFP vs QSFP
I-SFP I-QSFP
I-transceiver ye-SFP (Small Form-factor Pluggable) isebenzisa itshaneli enye ukuhambisa nokufumana idatha I-QSFP (iQuad Small Form-factor Pluggable) idibanisa iziteshi ezine kwimodyuli enye ukuze ifikelele kwi-bandwidth ephindwe kane.
I-SFP (1 Lane): Inendawo encinci enomzila omnye wokudlulisa (Tx) kunye nokwamkela (Rx). Ngokwesiko isebenzisa izihlanganisi ze-LC duplex okanye ze-SC simplex. I-QSFP (Iindlela ezi-4): Inendawo ebanzi. Ineendlela ezine zokudlulisa ezizimeleyo kunye neendlela ezine zokwamkela ezizimeleyo. Ngokwesiqhelo isebenzisa izihlanganisi ze-MPO/MTP ezinoxinano oluphezulu (kwii-parallel optics) okanye i-multiplexer yangaphakathi phezu kwe-LC duplex (ye-Wavelength Division Multiplexing).
Ifomu Factor Amaxabiso eDatha aPhambili Umgangatho oQhelekileyo / Iindidi Amatyala aqhelekileyo okusetyenziswa
I-SFP 1 Gbps 1G SFP Amakhonkco eshishini elidala
I-SFP+ 10 Gbps 10G SFP+ Iicores zamashishini zanamhlanje
I-SFP28 25 Gbps 25G SFP28 Amaziko edatha e-5G FTTA /
I-SFP56 50 Gbps 50G SFP56 Ikhompyutha engenazingcingo ephakathi, ekhethekileyo
QSFP+ 40 Gbps (4 x 10G) Isiseko se-40G-SR4 / LR4 Iileya zokusasazwa kweshishini
QSFP28 100 Gbps (4 x 25G) Isiseko se-100G-SR4 / LR4 Amalaphu e-data center-spine
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Iiklusta ze-AI kunye neziseko zelifu
I-KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Connector Transceiver ene-DDM

I-KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Connector Transceiver ene-DDM

Umthamo weSiteshi esiPhakamileyo: 40 Gbps ngemodyuli nganye

Ukuya kuthi ga kwi-11.1Gbps Izinga ledatha ngetshaneli nganye

Ubude obukhulu bekhonkco leekhonkco ze-100m kwi-OM3 multimode fiber Okanye iikhonkco ze-150m kwi-OM4 multimode fiber

Itekhnoloji ye-VCSEL ethembekileyo ephezulu ye-850nm

Iyakwazi ukuxhunywa ngombane

Uvavanyo lwedijithali oluhambelana ne-SFF-8436

Uluhlu lobushushu bokusebenza kwetyala: 0°C ukuya kwi-70°C

Ukusasazwa kwamandla < 0.7 W

I-KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Optical Transceiver

I-KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Optical Transceiver

+ I-KCO QSFP28 100G ER4 fiber optical transceiver idibanisa indlela yesamkeli kunye neyomthumeli kwimodyuli enye. Kwicala lokudlulisa, iindlela ezine zemithombo yedatha elandelelanayo ziyafunyanwa, ziphinde zisetyenziswe, kwaye zidluliselwe kubaqhubi be-laser abane.

+ Abaqhubi belaser balawula i-4-EML enobude bomda obuphakathi obuyi-1296 nm, 1300nm, 1305nm kunye ne-1309 nm.

I-KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 I-single mode fiber LR4 Transceiver

I-KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 I-single mode fiber LR4 Transceiver

I-KCO QSFP28 100G LR4I-optical Transceiver idibanisa indlela yesamkeli kunye neyomthumeli kwimodyuli enye. Kwicala lokudlulisa, iindlela ezine zemithombo yedatha elandelelanayo ziyafunyanwa, ziphinde zisetyenziswe, kwaye zidluliselwe kubaqhubi be-laser abane.

Abaqhubi be-laser balawula i-4-Distributed Feedback Laser (DFB) enobude bomda obuphakathi obuyi-1296 nm, 1300nm, 1305nm kunye ne-1309 nm. Imiqondiso ye-optical iphindaphindwa ibe yifayibha ye-single-mode ngesixhumi se-LC esisemgangathweni weshishini.

I-100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO Fiber Optic Transceiver

I-100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO Fiber Optic Transceiver

- P/N:I-KCO-QSFP28-100G-PSM4

- Ukuya kuthi ga kwi-26Gbps nge-bandwidth yetshaneli nganye;

- Iyahambelana ne-QSFP28 MSA

- Iitshaneli ezi-4 ze-1310nm DFP

- Uluhlu lwe-PIN photo detector lweziteshi ezi-4

- Ukufikelela kwi-2km ngaphezulu kwefayibha yemowudi enye eqhelekileyo

- Isixhumi se-MTP MPO siyahambelana

- Ujongano lombane olushushu olunokutsalwa

- Umbane omnye +3.3V osebenzayo

- Ubushushu boRhwebo ukusuka ku-0°C ukuya kuma-70°C

- Iyahambelana ne-IEEE 802.3ba kwiikhonkco ze-100GBASE-PSM4

- Icandelo elihambelana neRoHS

I-KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Optic Transceiver

I-KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Optic Transceiver

I-KCO QSFP28 100G ZR4 yenzelwe usetyenziso lonxibelelwano lwe-optical oluyi-80km.

Le modyuli iqulethe i-transmitter ye-optical eneendlela ezi-4, i-receiver ye-optical eneendlela ezi-4 kunye nebhloko yolawulo lweemodyuli kuquka ne-interface ye-serial ye-wire 2.

Imiqondiso ye-optical iphindaphindwa ibe yifayibha yemowudi enye ngesixhumi se-LC esisemgangathweni weshishini.

I-Cisco Compatible 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Duplex LC/UPC MMF Optical Transceiver Module

I-Cisco Compatible 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Duplex LC/UPC MMF Optical Transceiver Module

I-KCO QSFP28I-100G SRBD MMF 100M LC Duplex DOM

I-Cisco Compatible 100GBASE-SR SWDM4 QSFP28 Bi-Directional Optical Transceiver Module ye-Ethernet kunye neZiko leDatha (MMF, 850/880/910/940nm, 100m, LC, DOM)

I-Cisco Compatible 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 25G-SR ene-DDM

I-Cisco Compatible 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 25G-SR ene-DDM

Ukuya kuthi ga kwi-27.952 Gbps Izinga ledatha ngetshaneli nganye

Ubude obukhulu bekhonkco leekhonkco ze-150m kwi-OM4 multimode fiber

Itekhnoloji ye-VCSEL ethembekileyo ephezulu ye-850nm

Iyakwazi ukuxhunywa ngombane

Uvavanyo lwedijithali oluhambelana ne-SFF-8636

Iyahambelana ne-QSFP28 MSA

Uluhlu lobushushu bokusebenza kwetyala: 0°C ukuya kwi-70°C

Ukusasazwa kwamandla < 2.0W

I-KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Optical Fiber Transceiver 200G-FR4H OSFP SMF Duplex LC 2km

I-KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Optical Fiber Transceiver 200G-FR4H OSFP SMF Duplex LC 2km

- Ukuya kuthi ga kwi-50Gbps ngesantya sedatha ngetshaneli nganye nge-modulation ye-PAM4

- Ii-transmitters kunye nabamkeli beendlela ezimbini ze-duplex ezine

- Uluhlu oludibeneyo lwe-CWDM LD kunye ne-PD

- I-Duplex LC/UPC edibanisa i-interface ihambelana ne-interface

- Umbane omnye +3.3V 6, umsebenzi we-DDM uyasebenza

- Into yefom ye-QSFP56 eshushu enokutsalwa

- Ubude obuphezulu bonxibelelwano lwe-2km ngefayibha ye-SMF

- Ukusasazwa kwamandla aphantsi:<6.5W

- Isiqinisekiso sokhuseleko lwe-laser seklasi yoku-1 yamazwe ngamazwe

- Uluhlu lobushushu bokusebenza: 0~ +70

- Iyahambelana ne-ROHS

Iitransceiver ze-KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Fiber Optic

Iitransceiver ze-KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Fiber Optic

- Ihambelana ne-200GBASE-LR4, i-4x 26.5625 GBd PAM4

- Ihambelana ne-200GAUI-4, i-4x 26.5625 GBd PAM4

- Into yefom ye-QSFP56 eshushu enokutsalwa

- Ithobela i-QSFP+ 28 Gb/s

- Ubude obuphezulu bonxibelelwano lwe-10km nge-SMF

- Isixhumi se-Duplex LC

- Ukusasazwa kwamandla aphantsi: <8.0W

- Uluhlu lobushushu bokusebenza: 0 ukuya kwi-70ºC

I-KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver

I-KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver

- I-Transceiver ye-QSFP56 eshushu enokutsalwa

- Ixhasa i-bit rate ye-212,5Gbps

- Ukufikelela kwi-53.125Gbps ngesantya sedatha ngetshaneli nganye

- Izibuko le-QSFP56 elihambelana ne-SFF-8665;

- Ulawulo lwe-I2C oluhambelana ne-SFF-8636

- Iyahambelana ne-IEEE802.3cd 200GBASE-SR4

- Isixhobo sokudibanisa i-MPO-12 esinesiphelo se-UPC

- Ubude obuphezulu bonxibelelwano lwe-100m kwi-OM4 MMF

- Ubonelelo lwaMandla oluyi-3.3V olulodwa

- Ukusasazwa kwamandla aphantsi (<4.5W)

- Uluhlu lobushushu betyala lokusebenza: 0°C ukuya kuma-70°C

- Ukuthobela iRoHS

I-KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

I-KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

Ukuqhekeka kweModyuli ye-400GBASE-SR8 QSFP-DD Optical Transceiver ehambelanayo ukuya kwi-2 × 200G-SR4 kunye ne-8 × 50G-S

- Into eshushu enokutsalwa yefom yeQSFP-DD

- Ixhasa i-400Gb/s iyonke i-bit rate

- Ukufikelela kwi-53.125Gbps ngesantya sedatha ngetshaneli nganye

- Ubude obuphezulu bonxibelelwano yi-70m kwi-OM3 kunye ne-100m kwi-OM4

- Isixhobo sokudibanisa i-MPO

- Uluhlu lobushushu bekhesi: 0 ~ +70

- Ukusasazwa kwamandla: <10W

- Umbane omnye we-3.3V

- Ukuhambelana Kuqinisekisiwe kwi-Arista/NVIDIA/Cisco RoCE Networking

- I-bandwidth ephezulu

- Ulindelo oluphantsi

- Iyahambelana ne-QSFP-DD MSA

- Iyahambelana ne-IEEE 802.3cd

- Isikhalazo seRoHS

I-KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

I-KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

I-400GBASE-FR QSFP-DD 4 * 100G PAM4 Optical Transceiver Module 1310nm 2Km DOM MPO-12/APC Fiber Optic Equipment ehambelanayo

- Ihambelana ne-QSFP-DD MSA

- Isixhumi se-MPO-12 esinobuso obunekona ye-8°

- Ukusetyenziswa kwamandla <11 W

- Ubushushu bekheyisi yokusebenza buyi-0 ukuya kwi-70 ºC

- Ujongano lolawulo lwe-CMIS 4.0

- Imo yokuQhuba • 4x 100GBASE-FR1 iyahambelana ne-53.125GBd PAM4 • 100GAUI-2 iyahambelana ne-2x 26.5625 GBd PAM4

- Imo yoHlanganiso • Ithobela i-400GBASE-FR4 4x 53.125GBd PAM4 • Ithobela i-400GAUI-8 8x 26.5625 GBd PAM4

Ukusetyenziswa kwe-SFP kunye ne-QSFP kwisisombululo se-FTTH kunye ne-FTTA

Uyilo lweMetric I-FTTH (Ifayibha ukuya ekhaya) I-FTTA (Ifayibha ukuya kwi-Antenna)
Imodyuli yoMda (i-SFP) I-GPON / XGS-PON SFP (i-Simplex SC) I-25G SFP28 eCPRI (iDuplex okanye iBiDi LC)
Imodyuli engundoqo (i-QSFP) Iikhonkco zeNethiwekhi ze-QSFP28 / QSFP-DD Ukuqhekeka kweRadio ye-QSFP28 Port-to-SFP28
Iprotokholi ePhambili Ukufakwa kwe-Ethernet / ATM I-CPRI (4G) / i-eCPRI (5G ipakishwe)
Imfuneko yeXesha Elifutshane Ishishini (0°C ukuya kwi-70°C) ngaphakathi kwe-CO2 Imizi-mveliso (-40°C ukuya kuma-85°C) phezulu kwimasti
Ukusetyenziswa [ IOfisi Ephakathi ye-OLT ] ===( QSFP Uplink )===> [ Iswitshi Engundoqo ]
|
(i-PON SFP)
|
[ I-Passive Slitter ] ——> [ Ekhaya ONT / ONU ]
[ I-BBU Hub / DU ] ===( Ukuqhambuka kweQSFP28 )===> [ Iizibuko zeNqaba zeSFP28 ezi-4x ]
||
(Umboko othe nkqo)
||
[25G SFP28 RRU]
Iinethiwekhi ze-FTTH zixhomekeke kakhulu kwiindlela zePassive Optical Network (PON) ukusasaza i-intanethi ukusuka kwi-Ofisi Ephakathi (CO) ukuya kumakhaya abantu ngabanye. I-SFP28 (25G) Standard: Modern 5G Macro cells zisebenza kwii-transceivers ze-25G SFP28 ezakhelwe ngokukodwa iiprotocol ze-eCPRI (Enhanced Common Public Radio Interface).
Icala le-OLT: I-chassis ye-Optical Line Terminal (OLT) isebenzisa iimodyuli ze-PON SFP ezikhethekileyo (GPON, XGS-PON, okanye 25G-PON). Ezi zahlukile kuba ziyi-BiDi (Bidirectional) simplex SFPs—zisebenzisa isixhumi esinye se-SC ukuhambisa kubude obunye (umz., 1490nm) kwaye zifumane kwenye (umz., 1310nm) ukuze zikhonze ukuya kuthi ga kwiindlu ezingama-32 okanye ezingama-64 phezu komtya omnye wefayibha. Ukuqina Kwemizi-mveliso: Ii-SFT ezibekwe phezulu kwinqaba kufuneka zibe nomlinganiselo wobushushu bemizi-mveliso (-40°C ukuya kuma-85°C) ukuze zikwazi ukumelana nemozulu embi kakhulu yexesha lonyaka. Zihlanganiswe kwiindawo zangaphandle eziqinileyo ezifana neFullAXS okanye i-ODVA ngaphambi kokuba zixhunywe ngqo kwiRemote Radio Unit (RRU)
Icala le-ONT/ONU: Isiphelo senethiwekhi ye-optical esecaleni komthengi ngaphakathi kwekhaya okanye kwishishini sidla ngokusebenzisa iimodyuli eziqhelekileyo ze-1G SFP okanye ze-10G SFP+ ezifakwe kwisango lokuhlala. I-BiDi kunye ne-CWDM: Ukuze kongiwe ubunzima kunye nezixhobo zefayibha kwi-asethi yenqaba, iingcali zihlala zisebenzisa iimodyuli ze-BiDi SFP28 okanye ze-CWDM SFP28, zivumela iibhendi ezininzi zefrikhwensi ukuba zabelane ngemicu embalwa yeglasi.
Ukusetyenziswa kwe-QSFP (I-Central Office Core: Abasebenzisi basekhaya abasebenzisi iimodyuli ze-QSFP. Endaweni yoko, ii-transceivers ze-QSFP28 (100G) okanye ze-QSFP-DD (400G/800G) zisetyenziswa ngaphakathi kwi-Central Office. Zihlanganisa ithrafikhi enkulu edibeneyo evela kumakhadi amaninzi e-PON SFP kwaye ziyihambisa iye phezulu kwi-intanethi ebanzi. Ukusasazwa kwe-Breakout: Endaweni yokusebenzisa iintambo ze-SFP ezingama-24, i-router ye-baseband enoxinano oluphezulu iya kusebenzisa ii-port ze-QSFP28 (100G) kwimo yokuqhawuka. I-port enye ye-QSFP28 ihambelana nentambo ye-trunk ye-MPO eqhawuka ukusuka kwi-1 ukuya kwi-4, ihambisa ngokufanelekileyo iitshaneli ezine ezizimeleyo ze-25G eCPRI ukuya kwiirediyo ezine ezahlukeneyo.

Inkqubo
Inkqubo
Inkqubo