I-transceiver ye-SFP (Small Form-factor Pluggable) isebenzisa itshaneli enye ukuhambisa nokufumana idatha I-QSFP (iQuad Small Form-factor Pluggable) idibanisa iziteshi ezine kwimodyuli enye ukuze ifikelele kwi-bandwidth ephindwe kane.
I-SFP (1 Lane): Inendawo encinci enomzila omnye wokudlulisa (Tx) kunye nokwamkela (Rx). Ngokwesiko isebenzisa izihlanganisi ze-LC duplex okanye ze-SC simplex. I-QSFP (Iindlela ezi-4): Inendawo ebanzi. Ineendlela ezine zokudlulisa ezizimeleyo kunye neendlela ezine zokwamkela ezizimeleyo. Ngokwesiqhelo isebenzisa izihlanganisi ze-MPO/MTP ezinoxinano oluphezulu (kwii-parallel optics) okanye i-multiplexer yangaphakathi phezu kwe-LC duplex (ye-Wavelength Division Multiplexing).
Ifomu Factor Amaxabiso eDatha aPhambili Umgangatho oQhelekileyo / Iindidi Amatyala aqhelekileyo okusetyenziswa
I-SFP 1 Gbps 1G SFP Amakhonkco eshishini elidala
I-SFP+ 10 Gbps 10G SFP+ Iicores zamashishini zanamhlanje
I-SFP28 25 Gbps 25G SFP28 Amaziko edatha e-5G FTTA /
I-SFP56 50 Gbps 50G SFP56 Ikhompyutha engenazingcingo ephakathi, ekhethekileyo
QSFP+ 40 Gbps (4 x 10G) Isiseko se-40G-SR4 / LR4 Iileya zokusasazwa kweshishini
QSFP28 100 Gbps (4 x 25G) Isiseko se-100G-SR4 / LR4 Amalaphu e-data center-spine
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Iiklusta ze-AI kunye neziseko zelifu
I-KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 100G-DR

I-KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 100G-DR

- Iyahambelana ne-QSFP-DD MSA

- Iindlela ezine ze-Optical ezihambelanayo ze-1310nm

- I-IEEE 802.3bs 400GBASE-DR4 Inkcazelo Iyahambelana

- Iyahambelana neMfuneko yeRoHS

- Ukudluliselwa ukuya kuthi ga kwi-500m kwi-SMF ene-FEC

- 8×53. 125Gb/s Ujongano loMbane (400GAUI-8)

- Izinga leDatha 4* 106.25Gbps (PAM4) Ujongano olubonakalayo

- Uluhlu lobushushu bekheyisi: 0 ukuya kuma-70.C

- Ukusetyenziswa kwamandla aphezulu yi-10W

- Isixhumi se-MPO-12

- Imisebenzi yokuchonga yedijithali eyakhelwe ngaphakathi

I-KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Optical Transceiver Module

I-KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Optical Transceiver Module

- Iyahambelana ne-QSFP-DD MSA

- Iindlela ezi-4 ze-CWDM uyilo lwe-MUX/DEMUX

- Isixhumi se-Duplex LC

- Ukudluliselwa ukuya kuthi ga kwi-10km kwi-single mode fiber (SMF) nge-FEC

- 8×53.125Gb/s ujongano lombane (400GAUI-8)

- Izinga leDatha 106.25Gbps (PAM4) ngetshaneli nganye

- Uluhlu lobushushu bekhesi: 0 ~ +70

- Ukusetyenziswa kwamandla okuphezulu 9W

- Isikhalazo seRoHS

I-400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 100G-SR1.2

I-400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Ukuqhekeka ukuya kwi-4 x 100G-SR1.2

- QSFP-DD MSA

- 8x 53.125Gb/s Ujongano loMbane (400GAUI-8) oluhambelanayo

- Uthumelo lwe-MMF olufikelela kwi-150m OM5

- Isixhumi se-MPO-12 Optical

- I-RoHS iyahambelana

- Umbane omnye we-3.3 V

- Ukusetyenziswa kwamandla aphezulu 12W

- Ubushushu beTyala lokuSebenza: 0°C ukuya kuma-70°C

I-800GBASE 2xSR4/SR8 OSFP Finned Top PAM4 850nm 50m DOM Dual MPO-12/APC MMF Optical Transceiver Module

I-800GBASE 2xSR4/SR8 OSFP Finned Top PAM4 850nm 50m DOM Dual MPO-12/APC MMF Optical Transceiver Module

- I-Cisco OSFP-800G-VR8 Iyahambelana

- Iyahambelana neNVIDIA/Mellanox MMA4Z00-NS

- Iinethiwekhi ze-Arista ziyahambelana ne-OSFP-800G-2VSR4

- Iinethiwekhi zeJuniper ziyahambelana ne-OSFP-2X400G-VR4-P

- Iyahambelana ne-H3C OSFP-800G-VR8-MM850-DMPO

-Ezinye

I-800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Dual MPO-12/APC SMF Fiber Optical Transceiver Module

I-800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Dual MPO-12/APC SMF Fiber Optical Transceiver Module

Iyahambelana neNVIDIA/Mellanox MMS4X00-NM

I-Cisco OSFP-800G-DR8 iyahambelana nayo

Iinethiwekhi zeJuniper ziyahambelana ne-OSFP-2X400G-DR4-P

Iyahambelana ne-H3C OSFP800-800G-DR8-SM1310-DMPO

I-FTTH fiber optic network router Huawei HG8546M GPON ONU 4LAN 1 Voice WIFI 2 Antenna GPON ONU

I-FTTH fiber optic network router Huawei HG8546M GPON ONU 4LAN 1 Voice WIFI 2 Antenna GPON ONU

I-EchoLife HG8546M, iyunithi yenethiwekhi yokukhanya (i-ONU), sisisombululo se-home gateway esikumgangatho ophezulu kwi-Huawei FTTH. Ngokusebenzisa itekhnoloji ye-GPON, ukufikelela kwi-broadband ephezulu kuyabonelelwa kubasebenzisi basekhaya nabase-SOHO. I-H8546M ibonelela ngeeports ze-POTS ezi-1*, iiports ze-Ethernet ezizitshintsha ngokuzenzekelayo ze-1*GE+3* FE, kunye neeports ze-Wi-Fi ezi-2*. I-H8546M inezakhono zokudlulisa ezisebenzayo ukuqinisekisa amava amahle ngeenkonzo ze-VoIP, i-Intanethi kunye neevidiyo ze-HD. I-H8546M ibonelela ngesisombululo esigqibeleleyo sesiphelo kunye neenkonzo ezijolise kwixesha elizayo ezixhasa ukusasazwa kwe-FTTH.

Iyunithi yeNethiwekhi yeFiber Optical ye-1GE +1FE EPON XPON GPON GEPON HG8310 Optical Optical ONU ONT

Iyunithi yeNethiwekhi yeFiber Optical ye-1GE +1FE EPON XPON GPON GEPON HG8310 Optical Optical ONU ONT

- Ii-EPON ONT Series ziyilwe njengezisombululo ze-HGU (HomeGatewayUnit). – Usetyenziso lwe-FTTH lodidi lwabathwali lubonelela ngokufikelela kwinkonzo yedatha. – Uthotho lwe-EPON ONT lusekelwe kubuchwepheshe be-XPON obuvuthiweyo nobuzinzileyo, obungabizi kakhulu. – Lunokutshintsha ngokuzenzekelayo nge-EPON kunye ne-GPON xa lufikelela kwi-EPON OLT okanye kwi-GPON OLT. – Uthotho lwe-EPON ONT lusebenzisa ukuthembeka okuphezulu, ulawulo olulula, ukuguquguquka koqwalaselo kunye nesiqinisekiso somgangatho olungileyo wenkonzo (QoS) ukuze luhlangabezane nokusebenza kobugcisa kwemodyuli ye-China Telecom EPON CTC3.0 kunye ne-GPON Standard ye-ITU-TG.984.X

I-10/100M Fiber Optic Media Converter

I-10/100M Fiber Optic Media Converter

- Isiguquli semidiya se-fiber optic sisiguquli semidiya esiguquguqukayo se-10/100Mbps.

- Ingadlulisela i-100Base-TX yezibonakaliso zombane kwi-100Base-FX yezibonakaliso ezibonakalayo.

- Ujongano lombane luya kuthetha-thethana ngokuzenzekelayo ukuya kwi-10Mbps, okanye i-100Mbps Ethernet rate ngaphandle kohlengahlengiso.

- Ingandisa umgama wokudluliselwa ukusuka kwi-100m ukuya kwi-120km ngeentambo zobhedu.

- Izalathisi ze-LED zibonelelwe ukuze kuqinisekiswe ngokukhawuleza imeko yokusebenza kwezixhobo.

- Kukwakho nezinye izibonelelo ezininzi ezifana nokukhuselwa kokuzihlukanisa, ukhuseleko olulungileyo lwedatha, uzinzo lokusebenza kunye nokugcinwa lula.

- Sebenzisa iadaptha yamandla yangaphandle.

- I-Chipset: IC+ IP102

Izibuko eziyi-8 16 c++ gpon 5608T OLT

Izibuko eziyi-8 16 c++ gpon 5608T OLT

I-MA5608T Mini OLT yenzelwe ukujongana neFiber kwisimo (FTTP) okanye kwiimeko zokufakwa kwefiber enzulu apho itshasi enkulu ye-OLT isenokungalungelanga ngenxa yezizathu ezahlukeneyo. I-mini OLT MA5608T yeHuawei yenzelwe ukuba ibe yi-complement efanelekileyo kwezinye ii-OLT ezinkulu ze-MA5600 kwaye inikezela ngeempawu ezifanayo kunye nokusebenza komgangatho wokuthwala. Uyilo oluncinci nolungaphambili lwe-MA5608T lwenza ukuba ibe sisisombululo esifanelekileyo sokufakwa kwiindawo ezifana nee-huts ezixineneyo, iikhabhathi zangaphandle okanye izakhiwo ezingaphantsi. Ineendlela zombane ze-AC kunye ne-DC, uluhlu lobushushu olwandisiweyo, kwaye inika ukufakwa okulula.

I-SFP+ -10G-LR

I-SFP+ -10G-LR

• I-Transceiver ye-SFP+ ye-10Gb/s

• I-Hot Pluggable, i-Duplex LC, +3.3V, i-1310nm DFB/PIN, Imowudi enye, i-10km

Ukusetyenziswa kwe-SFP kunye ne-QSFP kwisisombululo se-FTTH kunye ne-FTTA

Uyilo lweMetric I-FTTH (Ifayibha ukuya ekhaya) I-FTTA (Ifayibha ukuya kwi-Antenna)
Imodyuli yoMda (i-SFP) I-GPON / XGS-PON SFP (i-Simplex SC) I-25G SFP28 eCPRI (iDuplex okanye iBiDi LC)
Imodyuli engundoqo (i-QSFP) Iikhonkco zeNethiwekhi ze-QSFP28 / QSFP-DD Ukuqhekeka kweRadio ye-QSFP28 Port-to-SFP28
Iprotokholi ePhambili Ukufakwa kwe-Ethernet / ATM I-CPRI (4G) / i-eCPRI (5G ipakishwe)
Imfuneko yeXesha Elifutshane Ishishini (0°C ukuya kwi-70°C) ngaphakathi kwe-CO2 Imizi-mveliso (-40°C ukuya kuma-85°C) phezulu kwimasti
Ukusetyenziswa [ IOfisi Ephakathi ye-OLT ] ===( QSFP Uplink )===> [ Iswitshi Engundoqo ]
|
(i-PON SFP)
|
[ I-Passive Slitter ] ——> [ Ekhaya ONT / ONU ]
[ I-BBU Hub / DU ] ===( Ukuqhambuka kweQSFP28 )===> [ Iizibuko zeNqaba zeSFP28 ezi-4x ]
||
(Umboko othe nkqo)
||
[25G SFP28 RRU]
Iinethiwekhi ze-FTTH zixhomekeke kakhulu kwiindlela zePassive Optical Network (PON) ukusasaza i-intanethi ukusuka kwi-Ofisi Ephakathi (CO) ukuya kumakhaya abantu ngabanye. I-SFP28 (25G) Standard: Modern 5G Macro cells zisebenza kwii-transceivers ze-25G SFP28 ezakhelwe ngokukodwa iiprotocol ze-eCPRI (Enhanced Common Public Radio Interface).
Icala le-OLT: I-chassis ye-Optical Line Terminal (OLT) isebenzisa iimodyuli ze-PON SFP ezikhethekileyo (GPON, XGS-PON, okanye 25G-PON). Ezi zahlukile kuba ziyi-BiDi (Bidirectional) simplex SFPs—zisebenzisa isixhumi esinye se-SC ukuhambisa kubude obunye (umz., 1490nm) kwaye zifumane kwenye (umz., 1310nm) ukuze zikhonze ukuya kuthi ga kwiindlu ezingama-32 okanye ezingama-64 phezu komtya omnye wefayibha. Ukuqina Kwemizi-mveliso: Ii-SFT ezibekwe phezulu kwinqaba kufuneka zibe nomlinganiselo wobushushu bemizi-mveliso (-40°C ukuya kuma-85°C) ukuze zikwazi ukumelana nemozulu embi kakhulu yexesha lonyaka. Zihlanganiswe kwiindawo zangaphandle eziqinileyo ezifana neFullAXS okanye i-ODVA ngaphambi kokuba zixhunywe ngqo kwiRemote Radio Unit (RRU)
Icala le-ONT/ONU: Isiphelo senethiwekhi ye-optical esecaleni komthengi ngaphakathi kwekhaya okanye kwishishini sidla ngokusebenzisa iimodyuli eziqhelekileyo ze-1G SFP okanye ze-10G SFP+ ezifakwe kwisango lokuhlala. I-BiDi kunye ne-CWDM: Ukuze kongiwe ubunzima kunye nezixhobo zefayibha kwi-asethi yenqaba, iingcali zihlala zisebenzisa iimodyuli ze-BiDi SFP28 okanye ze-CWDM SFP28, zivumela iibhendi ezininzi zefrikhwensi ukuba zabelane ngemicu embalwa yeglasi.
Ukusetyenziswa kwe-QSFP (I-Central Office Core: Abasebenzisi basekhaya abasebenzisi iimodyuli ze-QSFP. Endaweni yoko, ii-transceivers ze-QSFP28 (100G) okanye ze-QSFP-DD (400G/800G) zisetyenziswa ngaphakathi kwi-Central Office. Zihlanganisa ithrafikhi enkulu edibeneyo evela kumakhadi amaninzi e-PON SFP kwaye ziyihambisa iye phezulu kwi-intanethi ebanzi. Ukusasazwa kwe-Breakout: Endaweni yokusebenzisa iintambo ze-SFP ezingama-24, i-router ye-baseband enoxinano oluphezulu iya kusebenzisa ii-port ze-QSFP28 (100G) kwimo yokuqhawuka. I-port enye ye-QSFP28 ihambelana nentambo ye-trunk ye-MPO eqhawuka ukusuka kwi-1 ukuya kwi-4, ihambisa ngokufanelekileyo iitshaneli ezine ezizimeleyo ze-25G eCPRI ukuya kwiirediyo ezine ezahlukeneyo.

Inkqubo
Inkqubo
Inkqubo