1×8 1*8 1:8 Uhlobo lwetyhubhu encinci ye-PLC fiber optic splitter
Ingcaciso yeMveliso:
•I-PLC fiber optic splitter isekelwe kwiteknoloji yesekethe ye-planar Lightwave kunye nenkqubo yokulungelelanisa ngokuchanekileyo, inokwahlulahlula igalelo le-optical elinye/elimbini libe ziimveliso ezininzi ze-optical ngokulinganayo kwaye ichazwa njenge-1*N okanye i-2*N.
•I-PLC fiber optic splitter luhlobo lwesixhobo sokulawula amandla e-optical esenziwe kusetyenziswa itekhnoloji ye-silica optical waveguide.
•Inobukhulu obuncinci, ukuthembeka okuphezulu, ububanzi bobude bomsebenzi kunye nokufana okuhle phakathi kwetshaneli kunye netshaneli, kwaye isetyenziswa kakhulu kwiinethiwekhi zePON ukufezekisa ukwahlukana kwamandla esignali ye-optical.
•I-PLC fiber optic splitter inikezela ngokusebenza okuphezulu kwe-optical, uzinzo oluphezulu kunye nokuthembeka okuphezulu, ihlangabezana neemfuno ezahlukeneyo zesicelo kwiindawo ezahlukeneyo.
•I-1x8 PLC fiber optic splitter iza ne-1 input kunye ne-8 output. Ubude bekhebula lokufaka kunye nelokukhupha bunokuba yi-0.6m, 1.0m, 1.5m okanye ngokwezifiso. Ifumaneka ngeentlobo ezininzi zezixhumi ezifana nezi: SC/UPC, SC/APC, LC/UPC, LC/APC,
•I-1x8 PLC fiber optic splitter isetyenziswa ngokubanzi kwiibhokisi ezisi-8 ze-rack mount box zesakhelo sokusasazwa, okanye isetyenziswa ngokubanzi kwiibhokisi ezisi-8 ze-outdoor fiber optic distribution box.
Isicelo:
•Iinethiwekhi ze-FTTX
•Iinethiwekhi zePON
•Amakhonkco eCATV
•Unxibelelwano lweDatha
•Unxibelelwano ngefowuni
•Ukusasazwa kweSignali yoBoniso
Uphawu:
•Ukulahleka okuphantsi kokufakwa, ilahleko ephezulu yokubuya
•Uzinzo oluhle kakhulu lobushushu
•Ukuphindaphinda okuhle kunye nokutshintshiselana
•Ukunyamezela okugqwesileyo koomatshini
•Ixesha lokunyanga eliqinileyo kunye nolawulo lobushushu
•Imigangatho yovavanyo oluqinileyo kunye neendlela zomgangatho
•Ukhuseleko lwendalo (Ukuthobela i-ROHS)
•Intambo ye-fiber optical patch ingenziwa ngokwezifiso ngokweemfuno zabathengi (Isixhumi/ Ubude/ iphakheji eyenziwe ngokwezifiso...)
Ipharamitha:
| Uqwalaselo lweZibuko | 1*8 |
| Ukulahleka Kokufakwa (dB) Ubuninzi | 10.6 |
| Ukulahleka okufanayo (dB) | 1.0 |
| I-PDL(dB) | 0.25 |
| Ukulahleka okuxhomekeke kwiWavelength (dB) | 0.3 |
| Ukulahleka okuxhomekeke kwiqondo lobushushu (-40~85) (dB) | 0.4 |
Qaphela: Le parameter ingasentla yeyokwahlulahlula ngaphandle kwesixhumi.
| Uqwalaselo lweZibuko | 1*8 |
| Ukulahleka Kokufakwa (dB) Ubuninzi | 10.8 |
| Ukulahleka okufanayo (dB) | 1.0 |
| I-PDL(dB) | 0.2 |
| Ukulahleka Okuxhomekeke Kubude Begagasi (dB) | 0.3 |
| Ukulahleka okuxhomekeke kwiqondo lobushushu (-40~85°C) (dB) | 0.4 |
Qaphela: Le parameter ingasentla yeyokwahlulahlula ngesixhobo sokudibanisa.
Uvavanyo olupheleleyo olupheleleyo
| Ipharamitha | Isimboli | Ubuncinci. | Okuqhelekileyo | Ubuninzi. | Iyunithi | |
| Ubushushu bokugcina | TS | -40 |
| +85 | °C | |
| Ubushushu bokusebenza kweTyala | I-SFP+ -10G-LR | TA | 0 |
| 70 | °C |
| I-SFP+ -10G-LR-I | -40 |
| +85 | °C | ||
| Ubuninzi beVoltage yoNikezelo | I-Vcc | -0.5 |
| 4 | V | |
| Ubuntu bezizalwane | RH | 0 |
| 85 | % | |
Iimpawu zoMbane (PHEZULU = 0 ukuya kuma-70 °C, i-VCC = 3.135 ukuya kuma-3.465 Volts)
| Ipharamitha | Isimboli | Ubuncinci. | Okuqhelekileyo | Ubuninzi. | Iyunithi | Phawula |
| I-Voltage yokubonelela | I-Vcc | 3.135 |
| 3.465 | V |
|
| Ubonelelo lwangoku | I-Icc |
|
| 430 | mA |
|
| Ukutya umbane | P |
|
| 1.5 | W |
|
| Icandelo loMthumeli: | ||||||
| Impedance yokwahluka yokufaka | Rin |
| 100 |
| Ω | 1 |
| Ukunyamezelana kweVolthi ye-DC eNgenayo i-Tx (Ref VeeT) | V | -0.3 |
| 4 | V |
|
| Ukutshintsha kombane wokufaka okwahlukileyo | Vin,pp | 180 |
| 700 | mV | 2 |
| Dlulisa Khubaza iVolthi | VD | 2 |
| I-Vcc | V | 3 |
| Thumela Vumela iVoltage | VEN | UVee |
| I-Vee+0.8 | V |
|
| Icandelo loMmkeli: | ||||||
| Ukunyamezelana kweVoltage yeSiphumo esiPheleleyo esinye | V | -0.3 |
| 4 | V |
|
| I-Rx Output Dif Voltage | Vo | 300 |
| 850 | mV |
|
| Ixesha lokunyuka nokuwa kweRx Output | Tr/Tf | 30 |
|
| ps | 4 |
| Impazamo yeLOS | VImpazamo ye-LOS | 2 |
| I-VccUMBUKELI | V | 5 |
| I-LOS Eqhelekileyo | VIsiqhelo se-LOS | UVee |
| I-Vee+0.8 | V | 5 |
Amanqaku:1. Iqhagamshelwe ngqo kwiiphini zokufaka idatha ze-TX. Ukudibanisa i-AC ukusuka kwiiphini ukuya kwi-IC yomqhubi we-laser.
2. Ngokwe-SFF-8431 Rev 3.0.
3. Ukuphelisa umahluko kwi-100 ohms.
4. 20% ~80%.
5. I-LOS yimveliso evulekileyo yokuqokelela. Ifanele itsalwe phezulu nge-4.7k – 10kΩ kwibhodi yokusingatha. Ukusebenza okuqhelekileyo yi-logic 0; ukulahleka kwesiginali yi-logic 1. Umbane ophezulu wokutsalwa yi-5.5V.
IiParameters ze-Optical (TOP = 0 ukuya kwi-70°C, i-VCC = 3.135 ukuya kwi-3.465 Volts)
| Ipharamitha | Isimboli | Ubuncinci. | Okuqhelekileyo | Ubuninzi. | Iyunithi | Phawula |
| Icandelo loMthumeli: | ||||||
| Ubude beWave ephakathi | λt | 1290 | 1310 | 1330 | nm |
|
| ububanzi be-spectral | △λ |
|
| 1 | nm |
|
| Amandla oMbane aPhakathi | I-Pavg | -6 |
| 0 | i-dBm | 1 |
| Amandla okukhanya e-OMA | I-Poma | -5.2 |
|
| i-dBm |
|
| Umbane Ocinyiweyo ngeLaser | Poff |
|
| -30 | i-dBm |
|
| Umlinganiselo wokuphela | ER | 3.5 |
|
| dB |
|
| Isohlwayo sokuSasazwa kweTransmitter | I-TDP |
|
| 3.2 | dB | 2 |
| Ingxolo Yobukhulu Obuthelekisekayo | Rin |
|
| -128 | dB/Hz | 3 |
| Ukunyamezelana kokulahlekelwa yi-Optical Return |
| 20 |
|
| dB |
|
| Icandelo loMmkeli: | ||||||
| Ubude beWave ephakathi | λr | 1260 |
| 1355 | nm |
|
| Uvakalelo loMmkeli | USen |
|
| -14.5 | i-dBm | 4 |
| Uvakalelo oluxinezelekileyo (OMA) | USenST |
|
| -10.3 | i-dBm | 4 |
| I-Los Assert | I-LOSA | -25 |
| - | i-dBm |
|
| Idizethi yaseLos | I-LOSD |
|
| -15 | i-dBm |
|
| I-Los Hysteresis | I-LOSH | 0.5 |
|
| dB |
|
| Ukulayisha kakhulu | ngoMgqibelo | 0 |
|
| i-dBm | 5 |
| Ukubonakaliswa koMmkeli | Rrx |
|
| -12 | dB | |
Amanqaku:1. Amanani aphakathi anamandla anika ulwazi kuphela, ngokwe-IEEE802.3ae.
2. Inani le-TWDP lifuna ukuba ibhodi yomsingathi ihambelane ne-SFF-8431. I-TWDP ibalwa kusetyenziswa ikhowudi yeMatlab enikwe kwisiqendu 68.6.6.2 se-IEEE802.3ae.
3. Ukubonakaliswa kwe-12dB.
4. Iimeko zovavanyo lomamkeli oluxinzelelweyo ngokwe-IEEE802.3ae. Uvavanyo lwe-CSRS lufuna ukuba ibhodi yomamkeli ithobele i-SFF-8431.
5. Ukugqithisa kwe-receiver okuchazwe kwi-OMA naphantsi kwemeko enzima kakhulu yoxinzelelo olupheleleyo.
Iimpawu zeXesha
| Ipharamitha | Isimboli | Ubuncinci. | Okuqhelekileyo | UMax. | Iyunithi |
| Ixesha lokuQinisekisa le-TX_Disable | t_off |
|
| 10 | us |
| TX_Disable Ixesha Lokuchasa | t_on |
|
| 1 | ms |
| Ixesha Lokuqalisa Faka Ukuseta kwakhona kwe-TX_FAULT | t_int |
|
| 300 | ms |
| TX_FAULT ukusuka kwiSiphene ukuya kwiSiqinisekiso | impazamo |
|
| 100 | us |
| TX_Disable Ixesha Lokuqalisa Ukuseta ngokutsha | t_reset | 10 |
|
| us |
| Ukulahleka kweXesha lokuQinisekisa uphawu lomamkeli | TA,RX_LOS |
|
| 100 | us |
| Ukulahleka kweSignali yeSignali yoMmkeli | Td,RX_LOS |
|
| 100 | us |
| Ixesha lokutshintsha ixabiso | t_ratesel |
|
| 10 | us |
| Ixesha lewotshi ye-Serial ID | iwotshi ye-t_serial |
|
| 100 | kHz |
Isabelo sePin
Umzobo weBhodi yoMququzeleli weBhokisi yoQhagamshelo lweBloko Amanani ePin kunye neGama
Iinkcazo zomsebenzi wePin
| I-PIN | Igama | Umsebenzi | Amanqaku |
| 1 | I-VeeT | Umhlaba womthumeli wemodyuli | 1 |
| 2 | Impazamo ye-Tx | Impazamo yesixhobo sokuhambisa imodyuli | 2 |
| 3 | Khubaza i-Tx | Ikhubaza iTransmitter; Icima imveliso yelaser yetransmitter | 3 |
| 4 | I-SDL | I-2 wire serial interface data input/output (SDA) |
|
| 5 | I-SCL | Igalelo lewotshi ye-serial interface ye-wire 2 (SCL) |
|
| 6 | I-MOD-ABS | Imodyuli engekho, qhagamshela kwiVeeR okanye kwiVeeT kwimodyuli | 2 |
| 7 | I-RS0 | Linganisa i-select0, ngokuzikhethela lawula isamkeli se-SFP+. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s |
|
| 8 | I-LOS | Ukulahleka kweSignali yoMmkeli | 4 |
| 9 | I-RS1 | Linganisa i-select0, ngokuzithandela lawula i-SFP+ transmitter. Xa iphezulu, izinga lokufaka idatha >4.5Gb/s; xa iphantsi, izinga lokufaka idatha <=4.5Gb/s |
|
| 10 | I-VeeR | Umhlaba womamkeli wemodyuli | 1 |
| 11 | I-VeeR | Umhlaba womamkeli wemodyuli | 1 |
| 12 | RD- | Idatha eguqulweyo yomamkeli ibekwe ngaphandle |
|
| 13 | RD+ | Idatha engaguqukiyo yomamkeli ibekwe ngaphandle |
|
| 14 | I-VeeR | Umhlaba womamkeli wemodyuli | 1 |
| 15 | I-VccR | Ubonelelo lwe-3.3V yesamkeli seModule |
|
| 16 | I-VccT | Ubonelelo lwe-module transmitter 3.3V |
|
| 17 | I-VeeT | Umhlaba womthumeli wemodyuli | 1 |
| 18 | TD+ | Idatha eguqulweyo yetransmitter ikhutshwe |
|
| 19 | TD- | Idatha engaguqukiyo yokudlulisela idatha iphumile |
|
| 20 | I-VeeT | Umhlaba womthumeli wemodyuli | 1 |
Phawula:1. Izikhonkwane zomhlaba zemodyuli mazihlukaniswe kwibhokisi yemodyuli.
2. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.
3. Le pin mayitsalwe phezulu nge-4.7K-10Kohms ukuya kwi-VccT kwimodyuli.
4. Le pin yipini evulekileyo yokuqokelela/yokukhupha amanzi kwaye iya kutsalwa nge-4.7K-10Kohms ukuya kwi-Host_Vcc kwibhodi yokusingatha.
Ulwazi kunye noLawulo lwe-EEPROM ye-SFP Module
Iimodyuli ze-SFP zisebenzisa iprotocol yonxibelelwano lwe-serial ye-2-wire njengoko ichaziwe kwi-SFP -8472. Ulwazi lwe-serial ID lweemodyuli ze-SFP kunye neeparameter ze-Digital Diagnostic Monitor zinokufikelelwa nge-I2Ujongano lwe-C kwidilesi i-A0h kunye ne-A2h. Imemori idweliswe kwiTheyibhile 1. Ulwazi oluneenkcukacha lwe-ID (A0h) ludweliswe kwiTheyibhile 2, kunye no-tIinkcukacha zeDDM kwidilesi ye-A2h. Ukuze ufumane iinkcukacha ezithe vetshe ngemephu yememori kunye neenkcazo zebhayithi, nceda ujonge kwi-SFF-8472, “iDigital Diagnostic Monitoring Interface for Optical Transceivers”. Iiparameter zeDDM zilinganisiwe ngaphakathi.
Itafile1. Imephu yeMemori yoKuxilonga yeDijithali (Iinkcazo zeNdawo yeDatha eKhethekileyo).
Itheyibhile 2- I-EEPROM Serial ID Imemori Okuqulathwe (A0h)
| Idilesi yeDatha | Ubude (Ibhayithi) | Igama lika Ubude | Inkcazo kunye nesiqulatho |
| IiNdawo zoLwazi oluSisiseko | |||
| 0 | 1 | Isazisi | Uhlobo lwe-Serial transceiver (03h=SFP) |
| 1 | 1 | Igciniwe | Isihlonzi esongeziweyo sohlobo lwe-transceiver ye-serial (04h) |
| 2 | 1 | Isinxibelelanisi | Ikhowudi yohlobo lwesixhumi se-optical (07=LC) |
| 3-10 | 8 | I-Transceiver | Isiseko se-LR se-10G |
| 11 | 1 | Ukubhala ikhowudi | 64B/66B |
| 12 | 1 | BR, Igama eliyiNombolo | Isantya sebhawudi esiqhelekileyo, iyunithi ye-100Mbps |
| 13-14 | 2 | Igciniwe | (0000h) |
| 15 | 1 | Ubude (9um) | Ubude bekhonkco buxhaswa kwi-9/125um fiber, iiyunithi ze-100m |
| 16 | 1 | Ubude (50um) | Ubude bekhonkco buxhaswa kwi-fiber ye-50/125um, iiyunithi ze-10m |
| 17 | 1 | Ubude (62.5um) | Ubude bekhonkco buxhaswa kwi-fiber ye-62.5/125um, iiyunithi ze-10m |
| 18 | 1 | Ubude (ubhedu) | Ubude bekhonkco obuxhaswayo bekopolo, iiyunithi zeemitha |
| 19 | 1 | Igciniwe | |
| 20-35 | 16 | Igama lomthengisi | Igama lomthengisi we-SFP:I-VIP Fiber |
| 36 | 1 | Igciniwe | |
| 37-39 | 3 | I-OUI yomthengisi | I-ID ye-OUI yomthengisi we-SFP transceiver |
| 40-55 | 16 | I-PN yomthengisi | Inombolo yendawo: "I-SFP+ -10G-LR” (ASCII) |
| 56-59 | 4 | Umthengisi obhalisiweyo | Inqanaba lokuhlaziya inombolo yenxalenye |
| 60-62 | 3 | Igciniwe | |
| 63 | 1 | I-CCID | I-byte engabalulekanga kangako yesixa sedatha kwidilesi 0-62 |
| IiNdawo ze-ID ezandisiweyo | |||
| 64-65 | 2 | Ukhetho | Ibonisa ukuba zeziphi iimpawu ze-optical SFP ezisetyenziswayo (001Ah = LOS, TX_FAULT, TX_DISABLE zonke ziyaxhaswa) |
| 66 | 1 | BR, ubuninzi | Umda wesantya sebhithi ephezulu, iiyunithi ze-% |
| 67 | 1 | BR, umzuzu | Umlinganiselo wesantya sebhithi ophantsi, iiyunithi ze-% |
| 68-83 | 16 | Umthengisi SN | Inombolo yeserial (ASCII) |
| 84-91 | 8 | Ikhowudi yomhla | I-VIP FiberIkhowudi yomhla wokwenziwa |
| 92-94 | 3 | Igciniwe | |
| 95 | 1 | I-CCEX | Jonga ikhowudi yeeNdawo ze-ID ezandisiweyo (iidilesi ezingama-64 ukuya kuma-94) |
| IiNdawo zoLwazi oluKhethekileyo loMthengisi | |||
| 96-127 | 32 | Iyafundeka | I-VIP Fiberumhla othile, kufundwa kuphela |
| 128-255 | 128 | Igciniwe | Igcinelwe i-SFF-8079 |
Iimpawu zeMonitor yeDijithali yokuHlola
| Idilesi yeDatha | Ipharamitha | Ukuchaneka | Iyunithi |
| 96-97 | Ubushushu bangaphakathi beTransceiver | ±3.0 | °C |
| 100-101 | I-Laser Bias yangoku | ±10 | % |
| 100-101 | Amandla okuPhuma kweTx | ±3.0 | i-dBm |
| 100-101 | Amandla Okufaka i-Rx | ±3.0 | i-dBm |
| 100-101 | I-VCC3 Yangaphakathi Yokubonelela Ngevolthi | ±3.0 | % |
Ukuthotyelwa kweMithetho
II-SFP+ -10G-LR ihambelana ne-International Electromagnetic Compatibility (EMC) kunye neemfuno kunye nemigangatho yokhuseleko lwamazwe ngamazwe (jonga iinkcukacha kwiTheyibhile elandelayo).
| Ukukhupha ngombane (ESD) ukuya kwiiphini zombane | I-MIL-STD-883E Indlela 3015.7 | Iklasi 1(>1000 V) |
| Ukukhupha i-Electrostatic (ESD) ukuya kwiDuplex LC Receptacle | I-IEC 61000-4-2 I-GR-1089-CORE | Iyahambelana nemigangatho |
| I-electromagnetic Ukuphazamiseka (i-EMI) | I-FCC Icandelo 15 Udidi B I-EN55022 Udidi B (CISPR 22B) Iklasi yeVCCI B | Iyahambelana nemigangatho |
| Ukhuseleko lwamehlo ngeLaser | I-FDA 21CFR 1040.10 kunye ne-1040.11 EN60950, EN (IEC) 60825-1,2 | Iyahambelana ne-laser yeKlasi yoku-1 imveliso. |
Isekethe Ecetyiswayo
Isekethe yoNikezelo lwaMandla eBhodi yoMphathi eCetyisiweyo
I-Interface Circuit ecetyiswayo enesantya esiphezulu
Idatha yoBugcisa:
| Ubude befayibha | 1.0mokanye Elungiselelweyo |
| Uhlobo loQhagamshelo | I-SC,LC, FC okanye Elungiselelweyo |
| Uhlobo lweFiber ye-Optical | G652DG657A1 okanye Elungiselelweyo |
| Isikhokelo (dB) Ubuncinane * | 55 |
| Ilahleko yokubuyisela (dB) Ubuncinane * | 55 (50) |
| Ulawulo lwaMandla (mW) | 300 |
| Ubude beWave obusebenzayo (nm) | 1260 ~ 1650 |
| Ubushushu bokusebenza (°C) | -40 ~ +85 |
| Ubushushu bokugcina(°C) | -40 ~ +85 |
Umgca wemveliso: